One thousand cases of Pulsed-Field Ablation: Real-World insights
S Azevedo, R Almeida Carvalho, J Certo Pereira, I Coutinho Santos, R Montalvao, M Ines Soares, M Matias, D Gomes,
Key points
From the paper's conclusion- Conclusion In this comprehensive evaluation of 1000 PFA cases, the procedure showed a good efficacy and safety profile.
Abstract
Introduction Pulmonary vein isolation (PVI) is the standard catheter-based treatment for atrial fibrillation (AF). Due to its safety profile and efficacy, pulsed field ablation (PFA), a non-thermal energy, has been increasingly adopted as the default strategy across many centers. We aimed to analyse the real-world efficacy and safety of PFA for the treatment of atrial arrhythmias in a tertiary high-volume center. Methods All patients undergoing PFA for atrial tachyarrhythmias (i.e., AF and atrial flutter [AFL]) between July 2022 and November 2025 were included in the registry. Baseline characteristics included age, sex, left atrial volume (LAVi), left ventricular ejection fraction and history of prior catheter ablation. Procedural metrics included procedure duration, fluoroscopy time, and use of general anesthesia/sedation. The outcome of interest was arrhythmia recurrence, defined as AFL/ AF documented on ECG, Holter or clinical records after a 3-months period. Safety endpoint encompassed periprocedural complications, including cardiac tamponade, stroke, vascular access complications, and death. Results A total of 1000 patients were included (mean age 64±11years, 62,5% male, LAVI 62±24, 51% paroxysmal AF, 15% atypical atrial flutter, 21% redo procedures). The PFA systems used were Farapulse (73%), Varipulse (18%), Volt (7%) and Affera (2%). Regarding ablation sets, most patients underwent PVI alone (58%) or combined with other lesions posterior wall isolation (32,6%), posterior mitral isthmus line (10,5%), anterior line (2,6%) and cavotricuspid isthmus isolation (5,3%). Mean procedure time was 75±26min, and fluoroscopy duration was 8.5±6min. A total of 748 procedures (75%) were performed under general anesthesia (GA), whereas the others were under sedation with remifentanil, dexmedetomidine and midazolam. Periprocedural complications were documented in 0.8% (2 tamponade, 2 vascular access). During a median follow-up of 10 months (IQR 6-14), a total of 13% suffered arrhythmia recurrence. Results were not different whether performed under GA or sedation. Efficacy was not significantly different when compared to our center and other high-volume center registries of AF ablation using thermal energies (RF or cryo). Conclusion In this comprehensive evaluation of 1000 PFA cases, the procedure showed a good efficacy and safety profile. PFA has become the standard catheter-based treatment of AF.1000 PFA
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Contemporary pulsed field ablation systems for atrial fibrillation: a systematic review and network meta-analysisEuropean Heart Journal · 2026
- Pulsed Field Ablation for Atrial Fibrillation in Australia: A Large Tertiary Centre Analysis.Heart, lung & circulation · 2026
- Safety, Efficacy, and Effectiveness of Pulsed Field Ablation with Farapulse™ to Treat Atrial Fibrillation: A Prospective Single-center Study.The Journal of innovations in cardiac rhythm management · 2026
- Pulsed field ablation for atrial fibrillation ablation: a European Heart Rhythm Association surveyEP Europace · 2025
- Outcomes With Pulsed Field Ablation Versus Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation: A Meta‐AnalysisJournal of Arrhythmia · 2025
- Real-world one-year effectiveness of three pulsed field ablation systems for atrial fibrillationEuropean Heart Journal · 2026