Robotic-assisted electrode insertion in pediatric cochlear implantation: Implications for soft surgery and impedance outcomes.
Antonio Della Volpe, Fiammetta Margareta Korsch, Davide Stivalini, Antonietta Evangelista, Alfonso Varricchio, Antonietta De Lucia, Francesca Gioeli, Faralli Mario,
Otology and Cochlear Implant Unit, Department of Otolaryngology, Santobono-Pausilipon Children's Hospital, Naples, Italy. · Section of Otorhinolaryngology, Department of Medicine and Surgery University of Perugia, Perugia, Italy.
Key points
From the paper's conclusion- The findings indicate that the robotic method diminishes intracochlear injury, fostering a more advantageous biological milieu.
Abstract
Hearing loss is the most prevalent sensory impairment worldwide, profoundly affecting cognitive, linguistic, and social development, particularly throughout childhood. Cochlear implantation is the definitive treatment for severe-to-profound sensorineural hearing loss that does not respond to hearing aids. Cochlear preservation in children is essential because to their extended life expectancy and the possibility of reimplantation. The technique of electrode array insertion is pivotal among the factors affecting outcomes, as surgical trauma may induce intracochlear fibrosis and diminish performance. Electrical impedance serves as an effective biomarker for evaluating electrode-tissue interaction. Robotic surgery has been suggested to facilitate more precise and minimally invasive implantation. This study evaluated robotic-assisted electrode insertion against manual insertion in pediatric patients, examining surgery durations and impedance measurements. Twenty-three children aged 12 months to 7 years with substantial bilateral hearing loss were recruited and categorized into two groups: robotic electrode insertion (RobOtol®) and manual electrode insertion. Impedance data were obtained throughout the operation and at the nine-month mark. Robotic operations exhibited extended surgical durations (148.1 vs. 109.6 min; p = 0.029), alongside a reduced and more uniform insertion velocity (p = 0.0055). No problems were noted. The impedance values were markedly reduced in the robotic group both during the operation (p = 0.012) and after the 9-month follow-up (p = 0.032). The findings indicate that the robotic method diminishes intracochlear injury, fostering a more advantageous biological milieu. Although the surgical duration is extended, robotic surgery may enhance cochlear preservation and long-term outcomes. Additional prospective studies are required to validate this evidence.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Robotic‐Assisted Electrode Array Insertion Improves Stability of Acoustic Hearing ThresholdsThe Laryngoscope · 2026
- Impact of Robotic-Assisted Electrode Array Insertion on Neural Health and Hearing Outcomes in Cochlear Implant Recipients.Audiology & neuro-otology · 2026
- Early Clinical Experience With Robot-Assisted Electrode Insertion in Cochlear Implantation Using the Otoarm-Otodrive System.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2026
- Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Comparison of robotic-assisted and manual cochlear implant electrode array insertions considering cochlear geometric factors.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Guiding Cochlear Implant Electrode Insertion Using Impedance Measurements: A Computational Simulation Study.Sensors (Basel, Switzerland) · 2026