Risk-benefit profile of upper versus lower extremity peripherally inserted central catheter placement in neonates: A systematic review and meta-analysis.
Ying Xin Li, Qiong Chen, Yao Hua Wu, Xiu Juan Zhang, Hong Cheng, Xi Huang, Han Mei Peng, Yue Li,
Department of Neonatology Nursing, West China Second University Hospital, Sichuan University, Sichuan, China; Key Laboratory of Birth Defects and Related Diseases of Women and Children, Ministry of Education, Chengdu, Sichuan, China. · Key Laboratory of Birth Defects and Related Diseases of Women and Children, Ministry of Education, Chengdu, Sichuan, China; Department of Nursing, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China. Electronic address: huyanling0725@scu.edu.cn.
Key points
From the paper's conclusion- Crude observational evidence suggested a potential bidirectional risk-benefit profile across catheter-related outcomes. The findings should be interpreted cautiously because non-randomised designs remain susceptible to residual confounding. The observed associations may inform risk-informed, individualised site selection but do not establish a universally preferred site. Prospective studies with standardised outcomes and adjusted analyses are needed.
Abstract
BACKGROUND: The optimal insertion site for peripherally inserted central catheters in neonates remains uncertain. International guidelines differ in their recommendations regarding upper- versus lower-extremity placement, and existing systematic reviews are limited by small samples, narrow outcome coverage, or outdated evidence. OBJECTIVE: To compare the potential risk-benefit profile of upper- versus lower-extremity peripherally inserted central catheter placement in neonates. DESIGN: Systematic review and meta-analysis. METHODS: MEDLINE, Embase, CENTRAL, and CINAHL were searched from inception to January 6, 2026, for studies comparing upper- versus lower-extremity placement in neonates. Primary outcomes were venous thromboembolism, central line-associated bloodstream infection, and catheter tip malposition; secondary outcomes included phlebitis, catheter migration, catheter leakage, catheter occlusion, catheter breakage, total complications, dwell time, unplanned removal, pericardial or pleural effusion, sepsis, and all-cause mortality. Two reviewers independently extracted data and assessed risk of bias. Crude estimates were pooled, sparse and heterogeneous adjusted estimates were summarised narratively, and certainty of evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation approach. RESULTS: Twenty-one observational studies from 10 countries, involving 15,289 catheters, were included. For primary outcomes, upper-extremity placement was associated with a lower risk of venous thromboembolism (RR = 0.51, 95% CI 0.30-0.89; P = 0.017; low certainty) but higher risks of central line-associated bloodstream infection (RR = 1.44, 95% CI 1.07-1.95; P = 0.018; very low certainty) and catheter tip malposition (RR = 2.63, 95% CI 1.61-4.30; P < 0.001; very low certainty). For secondary outcomes, upper-extremity placement was associated with lower phlebitis risk (RR = 0.64, 95% CI 0.43-0.94; P = 0.022; low certainty) but higher risks of catheter migration (RR = 1.74, 95% CI 1.27-2.38; P < 0.001; low certainty), catheter leakage (RR = 2.24, 95% CI 1.35-3.73; P = 0.002; moderate certainty), and a marginally higher risk of unplanned removal (RR = 1.23, 95% CI 1.00-1.51; P = 0.048; very low certainty). A post hoc exploratory analysis suggested a possible higher risk of pericardial or pleural effusion (RR = 3.79, 95% CI 1.20-12.02; P = 0.024; very low certainty). No statistically significant between-site differences were observed for other secondary outcomes. CONCLUSIONS: Crude observational evidence suggested a potential bidirectional risk-benefit profile across catheter-related outcomes. The findings should be interpreted cautiously because non-randomised designs remain susceptible to residual confounding. The observed associations may inform risk-informed, individualised site selection but do not establish a universally preferred site. Prospective studies with standardised outcomes and adjusted analyses are needed. REGISTRATION: PROSPERO: CRD420251275788.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The applications, complications, and management of neonatal peripherally inserted central catheters (n-PICCs): a narrative review.Frontiers in pediatrics · 2026
- Selection of central venous access devices for neonates: an expert review.Expert review of medical devices · 2026
- Central line-associated bloodstream infection in preterm infants with umbilical venous catheters versus peripherally inserted catheters.Pediatric research · 2026
- Peripheral venous access in the neonate: current evidence, persistent uncertainties, and proposal of a structured insertion bundle.European journal of pediatrics · 2026
- Comparative safety and effectiveness of midline catheters vs. peripherally inserted central catheters: a systematic review and meta-analysis.Frontiers in cardiovascular medicine · 2026
- Peripheral IV Versus Extended Dwell Catheter Longevity in the PICU: Single-Center Retrospective Cohort, 2023-2024.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2026