Comparative safety and effectiveness of midline catheters vs. peripherally inserted central catheters: a systematic review and meta-analysis.
Mohammed Aljameie, Aya Ahmed Shimal, Mohamed H Mahmoud, Omar F Abbas, Alaa Mohammed Oudah, Marafi Jammaa Ahmed, Khadeeja Ali Hamzah, Anas Mansour,
Hammurabi College of Medicine, University of Babylon, Babil, Iraq. · College of Medicine, University of Baghdad, Baghdad, Iraq.
Key points
From the paper's conclusion- MCs are associated with a lower risk of bloodstream infections compared with PICCs. PICCs remain appropriate for long-term therapy, while MCs may represent a safer alternative for shorter courses. Device selection should be individualized based on patient risk factors, treatment duration, and clinical context.
Abstract
BACKGROUND & OBJECTIVE: Peripherally inserted central catheters (PICCs) and midline catheters (MCs) are widely used for intravenous therapy, but their relative safety and effectiveness remain uncertain. This systematic review and meta-analysis aimed to compare complication rates between PICCs and MCs. METHODS: We systematically searched PubMed, Scopus, Embase, and Web of Science for randomized controlled trials (RCTs) and observational studies evaluating PICCs vs. MCs. Risk of bias was assessed using the Cochrane RoB 2 tool for RCTs and the Newcastle-Ottawa Scale for observational studies. Meta-analyses were performed to calculate pooled risk ratios (RRs) and standardized mean differences (SMDs) with 95% confidence intervals (CIs). RESULTS: Fifteen studies (3 RCTs and 12 cohort studies) including over 27,000 patients were analyzed. PICCs were associated with a significantly higher risk of CRBSIs compared with MCs (RR = 4.18, 95% CI: 2.87-6.08; p < 0.01). No significant differences were observed between the two devices in rates of deep vein thrombosis (DVT), pulmonary embolism (PE), device failure, occlusion, dislodgement, catheter migration, phlebitis, or mortality. PICCs demonstrated longer dwell times (SMD = 0.68; 95% CI: 0.18-1.07; p < 0.01), consistent with their use in prolonged therapies. CONCLUSION: MCs are associated with a lower risk of bloodstream infections compared with PICCs. PICCs remain appropriate for long-term therapy, while MCs may represent a safer alternative for shorter courses. Device selection should be individualized based on patient risk factors, treatment duration, and clinical context.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Midline Venous Catheters Versus Peripherally Inserted Central Catheters for Intravenous Therapy: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.Journal of intensive care medicine · 2026
- Safety and efficacy of mini midline and peripheral venous catheters in intravenous therapy: a systematic review and meta-analysis.Frontiers in health services · 2026
- Comparison of Peripherally Inserted Central Catheters versus Central Venous Catheters in a Medical Intensive Care Unit: A Single-Center Retrospective Study.International journal of general medicine · 2026
- Clinical Application of Midline Catheters in an Acute Care Ward: A Single-center Retrospective Observational Study.Journal of community hospital internal medicine perspectives · 2026
- Clinical Utility of Ultrasound-Guided Midline Catheters in the Cardiovascular Intensive Care Unit.Journal of the College of Physicians and Surgeons--Pakistan : JCPSP · 2026
- Safety of Mini-Midline Catheters for Intravenous Antimicrobial Therapy Not Exceeding 14 Days: Treatment Completion Rate and Re-Catheterization Needs.Risk management and healthcare policy · 2026