Association between the 30-s chair stand test and peak oxygen uptake in patients undergoing cardiopulmonary exercise testing: A large retrospective internal and external validation study.
Takatoshi Iwasaki, Yoshiki Hata
Department of Rehabilitation, Minamino Cardiovascular Hospital, Japan. · Department of Cardiology, Minamino Cardiovascular Hospital, Japan.
Key points
From the paper's conclusion- CS-30 performance was independently associated with peak VO2. Although the prediction model showed moderate performance in the external validation cohort, CS-30 may serve as a simple complementary functional assessment associated with exercise capacity in clinical settings where CPET is not readily available.
Abstract
BACKGROUND: Peak oxygen uptake (peak VO2) assessed by cardiopulmonary exercise testing (CPET) is the gold standard for evaluating exercise capacity, but its routine use is limited in many clinical settings. This retrospective study investigated the association between 30-s chair stand test (CS-30) performance and peak VO2 and developed a prediction model with internal (Facility A) and external (Facility B) validation. METHODS: This study initially included 3652 patients who underwent CPET and physical function assessments between January 2020 and December 2025. After excluding 75 patients with a respiratory exchange ratio ≤ 1.04, 3577 patients were included in the analysis. A multivariable linear regression model including CS-30 performance, age, sex, and body mass index was developed using Facility A data and externally validated using Facility B data. RESULTS: CS-30 performance was independently associated with peak VO2 after multivariable adjustment. In the external validation cohort, predicted peak VO2 showed a moderate correlation with observed peak VO2 (r = 0.654, p < 0.001), with a root mean square error of 4.73 mL/kg/min and a mean bias of -2.23 mL/kg/min. CONCLUSIONS: CS-30 performance was independently associated with peak VO2. Although the prediction model showed moderate performance in the external validation cohort, CS-30 may serve as a simple complementary functional assessment associated with exercise capacity in clinical settings where CPET is not readily available.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Physiological Associations, Within-Session Repeatability, and Exploratory Prediction of Peak Oxygen Uptake Using the Revised 3-Minute Seated Stepping Test in Healthy Young Japanese Adults.Journal of functional morphology and kinesiology · 2026
- Prediction of oxygen uptake at peak exercise in patients with inflammatory bowel disease using submaximal cardiopulmonary exercise testing and the steep ramp test as a practical field test.PloS one · 2026
- Variable Degrees of Exercise Capacity Characterized by Comprehensive Cardiopulmonary Exercise Testing among Contemporary Adolescents.Pediatric cardiology · 2026
- ERS technical standard on reference values for cardiopulmonary exercise testing: summary report and a call for actionEuropean Respiratory Journal · 2026
- Development and external validation of a clinical model to estimate symptom-limited cardiopulmonary exercise testing parameters for prognostication in heart failureEuropean Heart Journal · 2026
- Percentile-based versus conventional thresholds in cardiopulmonary exercise testing: a retrospective cross-sectional study.ERJ open research · 2026