Variable Degrees of Exercise Capacity Characterized by Comprehensive Cardiopulmonary Exercise Testing among Contemporary Adolescents.
Takeshi Tsuda, Abby Skiena
Nemours Cardiac Center, Nemours Children's Hospital-Delaware, 1600 Rockland Rd, Wilmington, DE, 19803, USA. ttsuda@nemours.org. · Nemours Cardiac Center, Nemours Children's Hospital-Delaware, 1600 Rockland Rd, Wilmington, DE, 19803, USA.
Key points
From the paper's conclusion- We aimed to characterize underlying physiological mechanisms of variable exercise capacity in normal adolescents.
Abstract
We aimed to characterize underlying physiological mechanisms of variable exercise capacity in normal adolescents. Cardiopulmonary exercise testing (CPET) of disease-free (normal) adolescents was studied retrospectively. The cohort was divided into three groups based on %predicted maximum oxygen consumption (VO2)/kg: < 80% (poor), 80-100% (average), and > 100% (superior) performers. Peak and submaximal CPET parameters were analyzed to correlate with the level of exercise performance. Normal 115 males (29/43/43 in poor/average/superior groups) and 118 females (33/53/32) were studied. Age, peak (p) heart rate (HR), and HR reserve (HRR) were comparable in all groups. There was a positive correlation between pVO2/kg and peak oxygen pulse (OP)/kg (r = 0.93 and 0.95 in males and females, respectively) and between pVO2/kg and a slope of [VO2/kg]/heart rate (HR) (Δ[VO2/kg]/ΔHR) (r = 0.58 and 0.53 in males and females, respectively), whereas pVO2/kg revealed negative correlation with HR/[work rate (WR)/kg] slope (ΔHR/Δ[WR/kg]), HR-dependency (r = -0.33 and -0.27, in males and females, respectively), suggesting peak exercise performance is correlated with stroke volume (SV). Peak WR/kg, ventilatory anaerobic threshold (VAT)/kg, oxygen uptake efficiency slope (OUES)/kg, and submaximal slope of VO2/WR (ΔVO2/ΔWR) showed the same trend as peak VO2/kg. There were stepwise differences among three groups in regression lines of pWR-pVO2, VAT-pVO2, and peak minute ventilation (VE)-pVO2 relationships, suggesting peak exercise capacity was also influenced by aerobic work efficiency (muscle), endurance under an anaerobic condition, and ventilatory oxygenation efficiency (lung), respectively. Submaximal slope of VE/CO2 production (VCO2) (ΔVE/ΔVCO2) was comparable in all groups. Variable levels of exercise capacity in normal adolescents may be influenced by SV, central (lung) and peripheral (muscle) oxygen uptake efficiency, and exercise tolerance beyond anaerobic threshold, but not by chronotropic reserve or ventilatory efficiency of CO2 excretion.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cardiopulmonary exercise testing quotients: Expanding the concept beyond peak V . O 2 Q .Experimental physiology · 2026
- ERS technical standard on reference values for cardiopulmonary exercise testing: summary report and a call for actionEuropean Respiratory Journal · 2026
- Predictors of exercise capacity in adult Fontan patients: insights from cardiopulmonary exercise testing after total cavopulmonary connectionEuropean Heart Journal · 2026
- Association between the 30-s chair stand test and peak oxygen uptake in patients undergoing cardiopulmonary exercise testing: A large retrospective internal and external validation study.International journal of cardiology. Heart & vasculature · 2026
- Rethinking normality in cardiopulmonary exercise testing: why percentile-based thresholds deserve a greater role.ERJ open research · 2026
- Physiological Associations, Within-Session Repeatability, and Exploratory Prediction of Peak Oxygen Uptake Using the Revised 3-Minute Seated Stepping Test in Healthy Young Japanese Adults.Journal of functional morphology and kinesiology · 2026