iGIE : innovation, investigation and insights

Face validity of a new mixed-reality simulator for training endoscopic submucosal dissection: a Western pilot study.

Henriette Heinrich, Pieter Dewint, Phillipe Leclercq, Jelle Haringsma

Universitäres Bauchzentrum Clarunis, University of Basel, Basel, Switzerland. · Gastroenterology and Hepatology, UZA, Antwerp, Belgium.

Observational

Key points

From the paper's conclusion
  • The simulator demonstrates strong face validity and supports a realistic standardized skill acquisition in ESD. The simulator could provide a realistic and ethical alternative to current animal models and requires further study.

Abstract

BACKGROUND AND AIMS: Endoscopic submucosal dissection (ESD) is an effective but technically demanding procedure with a steep learning curve. Traditional training methods, including master courses, apprenticeship, and animal models, have ethical, financial, and logistical constraints. This pilot study evaluates the face validity of a novel mixed-reality simulator designed to enhance and maintain endoscopic dexterity in ESD training. METHODS: In this exploratory, prospective observational cohort study, 8 ESD trainees with prior advanced endoscopy experience, but limited ESD exposure, underwent a 2-day structured training using the EndoCubot (EndoRobotics, Seoul, South Korea) simulator with artificial laminated tissue (VTT [Versatile Training Tissue], KOTOBUKI Medical, Yashio, Japan). Performance was assessed pre- and post-training through a 5-minute dexterity test simulating circular incision with 40 achievable points, and a questionnaire evaluating simulator realism, satisfaction, and training effectiveness. Paired sample t tests (α = 0.05) and descriptive statistics were used for analysis. Results were reported as mean with standard deviation. RESULTS: On a 40-point scale, mean postcourse scores (34.7 [4.86]) were significantly higher than precourse scores (25.50 [0.76], P < .001), with a mean improvement of 9.25 points (95% confidence interval, 4.993-13.507, Hedges' g correction = 1.613). Survey results indicated high satisfaction (mean rating: 9.125/10) and strong agreement on the simulator's realism and effectiveness. CONCLUSIONS: The simulator demonstrates strong face validity and supports a realistic standardized skill acquisition in ESD. The simulator could provide a realistic and ethical alternative to current animal models and requires further study.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Face validity of a new mixed-reality simulator for training endoscopic submucosal dissection: a Western pilot study — Science Skim