Pulsed Field or Cryoballoon Pulmonary Vein Isolation for Atrial Fibrillation in Heart Failure with Reduced Ejection Fraction.
Andreas A Boehmer, Maura M Zylla, Sebastian Feickert, Henrike A K Hillmann, Katia Dyrda, Simon Lussier, Dorina Stangl, Veronica Buia,
Department of Cardiology, St. Josefs-Hospital Wiesbaden, Wiesbaden, Germany; Department of Medicine, Montreal Heart Institute, Université de Montreal, Canada; Department of Cardiology, Kerckhoff Heart Center, Kerckhoff Campus of the Justus Liebig University Giessen, Bad Nauheim, Germany. Electronic address: aboehmer@joho.de. · Department of Cardiology, Medical University Hospital Heidelberg, Heidelberg, Germany.
Key points
From the paper's conclusion- In patients with AF and HFrEF, PFA-based PVI achieves similar rhythm-control efficacy and safety compared with CBA, while significantly enhancing procedural efficiency.
Abstract
BACKGROUND: Atrial fibrillation (AF) and heart failure with reduced ejection fraction (HFrEF) frequently coexist, worsening prognosis. While catheter ablation confers clinical benefits in this high-risk population, comparative data between novel non-thermal pulsed field ablation (PFA) and established cryoballoon ablation (CBA) for AF-therapy in patients with HFrEF are limited. OBJECTIVE: To compare the efficacy and safety of PFA- with CBA-based pulmonary vein isolation (PVI) in patients with AF and HFrEF (left ventricular ejection fraction ≤40%). METHODS: This retrospective, international multicenter study included patients with HFrEF undergoing first-time PVI-only procedures between 2018 and 2025. Propensity-score matching (1:1 ratio) was applied to balance baseline characteristics. The primary efficacy endpoint was the first recurrence of any atrial tachyarrhythmia after a 3-month blanking period. Secondary measures included safety events and procedural efficiency. RESULTS: A total of 700 patients from 12 German and Canadian centers were included, with 420 patients analyzed following propensity-score matching. At 12 months, freedom from atrial tachyarrhythmia recurrence with PFA was comparable to CBA (Kaplan-Meier estimates, 65.0% vs. 67.8%; hazard ratio, 1.09; 95% CI, 0.77 to 1.55; P=0.61). No statistically significant differences in observed safety outcomes were detected. PFA significantly improved procedural efficiency with shorter total procedure duration (58±22min vs. 72±22min; P<0.001), left-atrial dwell time (42±16min vs. 52±17min; P<0.001) and lower contrast dye use (0 ml [IQR 0-15] vs. 47 ml [IQR 30-56], P<0.001). CONCLUSIONS: In patients with AF and HFrEF, PFA-based PVI achieves similar rhythm-control efficacy and safety compared with CBA, while significantly enhancing procedural efficiency.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Cryoballoon and Pulsed Field Ablation in Patients with Symptomatic Atrial Fibrillation: First 6-Month Experience.Anatolian journal of cardiology · 2026
- Pulsed field, cryoballoon or radiofrequency catheter ablation of atrial fibrillation in hypertrophic cardiomyopathy.Heart rhythm · 2026
- Safety and Efficacy of Pulsed-Field Ablation With a Pentaspline Ablation Catheter Versus Cryoablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis.Clinical cardiology · 2026
- Pulsed Field Ablation Versus Thermal Ablation for First-Time Pulmonary Vein Isolation in Atrial Fibrillation: A Systematic Review and Meta-Analysis.Journal of arrhythmia · 2026
- Pulsed Field Ablation Is Associated With Favorable Outcomes After Atrial Fibrillation Ablation: Insights From the Polish National Ablation Registry (POL-AR).Journal of cardiovascular electrophysiology · 2026
- Efficiency, Efficacy, and Energy-Specific Safety of Pulsed Field Versus Thermal Ablation in Paroxysmal Atrial Fibrillation: Insights From Contemporary Randomized Data (the E3-PFA Collaboration).Circulation. Arrhythmia and electrophysiology · 2026