Pulmonary vein narrowing after voltage-guided adjunctive pulmonary vein sleeve pulsed field ablation.
Takehito Sasaki, Taiki Masuyama, Kentaro Minami, Shingo Yoshimura, Suguru Nishiuchi, Akiko Kodama, Kojiro Hattori, Kenichi Kaseno,
Division of Cardiology, Gunma Prefectural Cardiovascular Center, 3-12 Kameizumi-machi, Maebashi City, Gunma, 371-0004, Japan. · Department of Cardiovascular Medicine, Dokkyo Medical University, 880 Kitakobayashi, Mibu-machi, Shimotsuga-gun, Tochigi, 321-0293, Japan.
Key points
From the paper's conclusion- In patients undergoing an initial PFA-based PVI, no significant PV narrowing was observed approximately six months after voltage-guided adjunctive PV sleeve PFA using a pentaspline catheter. Further controlled studies with larger populations and longer follow-up are needed to better characterize the safety and clinical utility of this strategy.
Abstract
BACKGROUND: Pulsed field ablation (PFA) for pulmonary vein (PV) isolation (PVI) has been associated with a low risk of PV stenosis when performed using the standard ostial workflow. However, the risk of PV narrowing after adjunctive PV sleeve PFA remains insufficiently evaluated. OBJECTIVE: To assess PV narrowing after voltage-guided adjunctive PV sleeve PFA. METHODS: We retrospectively studied 147 patients who underwent an initial pentaspline PFA-based PVI for atrial fibrillation. In addition to standard ostial PVI, voltage-guided PFA applications were delivered to target PV sleeve potentials identified on pre-ablation voltage mapping. Contrast-enhanced computed tomography was performed before and approximately six months after ablation. PV cross-sectional areas (PVAs) were measured at predefined levels, and the maximum PVA reduction rate was defined as ΔPVA. Significant PV narrowing was defined as ΔPVA ≥25%. RESULTS: Post-ablation PVA was significantly smaller than pre-ablation PVA at all PV sites. The median ΔPVA was 5.4%, 6.4%, 4.6%, and 4.0% in the left superior, left inferior, right superior, and right inferior PVs, respectively, and differed significantly among the four PV sites (P = 0.012). No significant PV narrowing was observed in this cohort. CONCLUSIONS: In patients undergoing an initial PFA-based PVI, no significant PV narrowing was observed approximately six months after voltage-guided adjunctive PV sleeve PFA using a pentaspline catheter. Further controlled studies with larger populations and longer follow-up are needed to better characterize the safety and clinical utility of this strategy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of pulsed-field ablation of the right superior pulmonary vein on conduction block in the superior vena cavaEuropean Heart Journal · 2026
- Posterior Pulmonary Vein Isolation Lesion Spacing and Left Atrial Posterior Wall Narrowing During Pulsed Field AblationJournal of Arrhythmia · 2026
- Reversible posterior wall electroporation following pentaspline versus balloon-in-basket pulsed-field ablationEuropean Heart Journal · 2026
- Left atrial remodelling and functional consequences after pulsed-field ablation: comparison of pulmonary vein isolation alone versus extensive lesion setsEuropean Heart Journal · 2026
- Contact Index–Guided Pulsed Field Ablation: A Two‐Phase Validation of the Impedance Change Threshold to Prevent Acute Pulmonary Vein GapsJournal of Arrhythmia · 2026
- Optimized workflow for pentaspline PFA and its impact on PVI durability: evidence from systematic remappingEP Europace · 2026