Incidence, Modifiable Risk Factors, and Management of Cardiomyopathy After Ventricular Leadless Pacemaker Implantation.
Thomas Van Weyenbergh, Rik Willems, Gabor Vörös, Bert Vandenberk, Patricia Poels, Axel Dorrestijn, Christophe Garweg
University Hospitals Leuven, Leuven, Belgium; Department of cardiovascular sciences, KU Leuven, Leuven, Belgium. · University Hospitals Leuven, Leuven, Belgium.
Key points
From the paper's conclusion- Cardiomyopathy occurred in a substantial proportion of LPM recipients. RVOT implantation was associated with lower cardiomyopathy incidence and slower LVEF decline, whereas Micra AV implantation did not improve clinical outcomes. However, higher AV synchrony was linked to slower LVEF deterioration.
Abstract
BACKGROUND: Leadless ventricular pacemakers (LPM) provide only RV pacing, which may lead to pacing-induced cardiomyopathy (PICM). It is unclear whether LPM implant site or atrioventricular synchronous pacing using the Micra AV device influence PICM occurrence. OBJECTIVE: To evaluate the incidence of cardiomyopathy after LPM implantation and explore the association of implant site and AV-synchronous pacing with cardiomyopathy risk and LVEF evolution. METHODS: This single-center retrospective study included 401 patients implanted with an LPM (Micra AV n=145) between July 2015 and March 2025. PICM was defined as cardiomyopathy (≥10% LVEF decline to <50%) in the presence of >20% ventricular pacing, where pacing was considered the primary cause. Risk factors for cardiomyopathy and LVEF evolution were assessed using Cox regression and mixed-effects modelling. RESULTS: Over a median follow-up of 33.0 months, all-cause cardiomyopathy occurred in 13.6% (4.8%/year), while PICM was identified in 5.5% (1.9%/year). RVOT implantation was independently associated with a lower incidence of all-cause cardiomyopathy (HR 0.48, P=0.019), and a slower LVEF decline (-0.56%/year vs -1.43%/year, P=0.013) compared with mid-septal implantation. Device type (Micra AV vs VR) was not associated with clinical outcomes or LVEF evolution. Among patients developing cardiomyopathy, 92.7% were medically treated, with 57.9% achieving ≥10% LVEF improvement, and 36.8% complete recovery. CRT upgrade was uncommon (7.3%). CONCLUSION: Cardiomyopathy occurred in a substantial proportion of LPM recipients. RVOT implantation was associated with lower cardiomyopathy incidence and slower LVEF decline, whereas Micra AV implantation did not improve clinical outcomes. However, higher AV synchrony was linked to slower LVEF deterioration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Leadless Pacemaker Implant Location as a Predictor of Pacing Induced Cardiomyopathy.Pacing and clinical electrophysiology : PACE · 2026
- Incidence of Pacing-Induced Cardiomyopathy in Active-Fixation Leadless Pacemakers.Journal of cardiovascular electrophysiology · 2026
- Pacing‐Induced Cardiomyopathy in Leadless and Transvenous Pacemakers: A Meta‐Analysis and Meta‐RegressionPacing and Clinical Electrophysiology · 2026
- High right ventricular pacing burden is associated with heart failure following leadless pacemaker implantationsEuropean Heart Journal · 2026
- Leadless Versus Transvenous Single‐Chamber Ventricular Pacemakers: Real‐World Evidence From Aveir VR Coverage With Evidence Development StudyJournal of the American Heart Association · 2025
- Leadless Pacemaker, Right Ventricular Pacing Burden, and Heart Failure.Heart rhythm · 2026