Unipolar Electrograms at the Pulmonary Vein Antrum: Spatial and Directional Heterogeneity with Distinct Postablation Morphologies.

Ungjeong Do, Gi-Byoung Nam

Department of Cardiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea. · Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea. Electronic address: gbnam@amc.seoul.kr.

Key points

From the paper's conclusion
  • Antral PV U-EGMs frequently represent composites of near- and far-field signals with spatial heterogeneity and direction-dependent variation. Postablation responses are diverse, including S-wave disappearance, residual negativity, often reflecting contributions from overlapping far-field components, and newly developed positive deflections. PV-antral U-EGMs should be interpreted in the context of their composite nature.

Abstract

BACKGROUND: Disappearance of the near-field S-wave in the unipolar electrogram (U-EGM) is commonly used to assess lesion formation during pulmonary vein (PV) isolation; however, interpretation of U-EGMs in anatomically complex atrial regions remains uncertain. OBJECTIVE: We aimed to characterize spatial, directional, and postablation changes in antral PV U-EGMs, and evaluate the limitations of conventional waveform interpretation. METHODS: In 15 patients undergoing radiofrequency ablation for atrial fibrillation, U-EGMs were recorded at 116 antral PV sites during sinus rhythm and distal coronary sinus (CS) pacing before and after ablation. U-EGM morphology and R- and S-wave amplitudes were analyzed. RESULTS: Baseline U-EGMs showed spatial heterogeneity, with a small r and deep S in the right anterior PV antrum transitioning to a positive-dominant morphology (Rs) in the left-lower PV antra. Distal CS pacing altered the activation sequence, causing direction-dependent changes, most prominently in the right PV antrum. After ablation, overall S-wave amplitude decreased from -0.94 ± 0.70 to -0.08 ± 0.55 mV (P<0.001). Residual negative deflections ≥0.5 mV persisted in 18.1% (21/116) of recordings, frequently in association with direction-dependent far-field activity. Newly developed positive deflections ≥1.0 mV were observed in 17/116 sites (14.7%; mean 1.42 ± 0.42 mV), predominantly in the right-sided antra. CONCLUSIONS: Antral PV U-EGMs frequently represent composites of near- and far-field signals with spatial heterogeneity and direction-dependent variation. Postablation responses are diverse, including S-wave disappearance, residual negativity, often reflecting contributions from overlapping far-field components, and newly developed positive deflections. PV-antral U-EGMs should be interpreted in the context of their composite nature.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers