Practical Approaches to Coronary Venous Ethanol Ablation for Refractory Ventricular Arrhythmias: Technique Selection and Clinical Outcomes.
Takeshi Mori, Miyabi Ishikawa, Kohei Kitamura, Mami Fukuju, Teppei Funasaka, Makito Kaneshiro, Nobuo Ishiguro, Akimitsu Tanaka,
Department of Cardiology, Nagoya Tokushukai General Hospital, Kasugai, Aichi, Japan. · Department of Cardiology, Nagoya Tokushukai General Hospital, Kasugai, Aichi, Japan. Electronic address: kkato@fujita-hu.ac.jp.
Key points
From the paper's conclusion- In patients with VAs refractory to endocardial RFA, CVEA was associated with favorable acute and long-term outcomes, with no fatal complications. Technique selection should be tailored to the venous anatomy, with judicious ethanol volume adjustment.
Abstract
BACKGROUND: Coronary venous ethanol ablation (CVEA) is a promising alternative for refractory ventricular arrhythmias (VAs); however, it has limited availability, lacks guideline support, and comprises heterogeneous procedural techniques. OBJECTIVE: To evaluate the acute efficacy, safety, and long-term outcomes of CVEA in refractory VAs and outline practical techniques of CVEA. METHODS: Consecutive patients undergoing VA ablation at our center between December 2017 and December 2025 were screened; CVEA was performed after unsuccessful endocardial RFA. We performed CVEA using either tip injection, conventional double-balloon, or modified double-balloon techniques based on venous anatomy. RESULTS: Among 204 consecutive patients undergoing VA ablation, 55 had VAs refractory to endocardial RFA. Of these, 42 with a coronary venous electrogram preceding VA onset by >20 ms underwent CVEA, including 33 with premature ventricular contraction (PVC) and 9 with ventricular tachycardia (VT). Acute success was achieved in 32/33 patients with PVC and all patients with VT. During a median follow-up of 1,024 days, long-term success was achieved in 22 patients with PVC and 5 with VT. No association was observed between intraprocedural findings and long-term recurrence. CVEA-related procedural complications occurred in 13 patients, with no fatal events reported. Exploratory analyses suggested favorable outcomes for the modified double-balloon technique in anatomically selected cases and an association between higher ethanol volume and ethanol-related complications. CONCLUSION: In patients with VAs refractory to endocardial RFA, CVEA was associated with favorable acute and long-term outcomes, with no fatal complications. Technique selection should be tailored to the venous anatomy, with judicious ethanol volume adjustment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Vein of marshall ethanol infusion at the time of repeated ablation in persistent atrial fibrillation patients (Italian VERA Study)European Heart Journal · 2026
- Successful pulsed field ablation for refractory premature ventricular contractions using a novel dual-energy focal catheter: a case report.European heart journal. Case reports · 2026
- Radiofrequency Catheter Ablation of Atrial Fibrillation in Patients with Anomalous Pulmonary Venous Return: A Multicenter Case Series.medRxiv · 2026
- Enhancing Persistent Atrial Fibrillation Ablation: The Added Value of Vein of Marshall Ethanol Infusion in a Tailored Strategy.Journal of cardiovascular electrophysiology · 2026
- Dual-Energy Pulsed Field and Radiofrequency Ablation With a Contact Force-Sensing Focal Catheter for Ventricular Arrhythmias: Initial Clinical ExperiencemedRxiv · 2026
- Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States.Journal of cardiovascular electrophysiology · 2026