Successful pulsed field ablation for refractory premature ventricular contractions using a novel dual-energy focal catheter: a case report.
Kohei Ukita, Roman Mamaev, Sorin Stefan Popescu, Roland Richard Tilz
Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, 23562 Lübeck, Germany.
Key points
From the paper's conclusion- We report successful PFA for RFA-refractory PVCs using this technology.
Abstract
BACKGROUND: Radiofrequency ablation (RFA) is an established therapy for symptomatic premature ventricular contractions (PVCs), but arrhythmias from deep intramural substrates may remain refractory. Pulsed field ablation (PFA) is a nonthermal modality with myocardial selectivity, and dual-energy focal catheters allow delivery of both RFA and PFA using a single device. We report successful PFA for RFA-refractory PVCs using this technology. CASE SUMMARY: An 81-year-old man with ischaemic cardiomyopathy and symptomatic monomorphic PVCs was referred after failed prior RFA of both right ventricular outflow tract (RVOT) and left ventricular outflow tract (LVOT). During repeat ablation, activation mapping identified earliest activation at the septal RVOT and anterior LVOT. Using a dual-energy focal catheter, sequential RFA and PFA were delivered at both sites. In the RVOT, PFA caused only transient suppression with recurrence of PVCs. In the LVOT, the first PFA application failed to eliminate PVCs, whereas additional applications resulted in immediate and sustained suppression. No complications occurred, and the patient remained free of PVCs during follow-up. DISCUSSION: This case demonstrates the feasibility of dual-energy focal catheter-based PFA for ventricular arrhythmias refractory to RFA. The elimination of PVCs after repeated PFA suggests that multiple PFA applications may enhance lesion formation in deep intramural substrates. However, this observation should be interpreted cautiously because histological confirmation was unavailable and alternative explanations, including cumulative energy exposure and autonomic variability during conscious sedation, cannot be excluded. Further studies are required to define optimal energy strategy, lesion characteristics, and long-term outcomes of dual-energy ablation for ventricular arrhythmias.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- First United States Experience With Focal Pulsed-Field Ablation Using the FARAPOINT Catheter for Refractory Ventricular Tachycardia.Journal of cardiovascular electrophysiology · 2026
- Dual-Energy Pulsed Field and Radiofrequency Ablation With a Contact Force-Sensing Focal Catheter for Ventricular Arrhythmias: Initial Clinical ExperiencemedRxiv · 2026
- Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States.Journal of cardiovascular electrophysiology · 2026
- Para-His periaortic VT ablation with focal pulsed-field energyHeart Rhythm · 2026
- Safety and Effectiveness of a Novel Dual-Energy Radiofrequency/Pulsed Field Ablation Catheter: 12 Month Results of the FlexPulse Study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Pulsed Field Ablation for Atrial Fibrillation: Mechanism, Clinical Evidence, and Emerging Applications.Cureus · 2026