Pancreatobiliary Advanced Medical Center, Osaka Medical and Pharmaceutical University Hospital, Osaka, Japan; 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan; Endoscopy Center, Osaka Medical and Pharmaceutical University Hospital, Osaka, Japan. Electronic address: oguratakeshi0411@yahoo.co.jp. · Pancreatobiliary Advanced Medical Center, Osaka Medical and Pharmaceutical University Hospital, Osaka, Japan; 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan.

Observational

Key points

From the paper's conclusion
  • A three-factor model based on anatomical variables assessable on EUS before bile duct puncture showed excellent apparent discrimination and good calibration for predicting first-attempt technical failure during EUS-HGS. This internally validated model provides a preliminary framework for pre-puncture risk estimation; however, its clinical application remains hypothesis-generating and requires prospective multicenter external validation before implementation in clinical decision-making.

Abstract

BACKGROUND AND AIMS: Technical failure during EUS-guided hepaticogastrostomy (EUS-HGS) remains clinically relevant, yet most previously reported predictors are assessed only after bile duct puncture or guidewire manipulation has already been attempted. We aimed to identify EUS-assessable anatomical factors measurable before bile duct puncture and to develop an internally validated model for predicting first-attempt technical failure during EUS-HGS. METHODS: We retrospectively analyzed consecutive patients who underwent attempted EUS-HGS between January 2015 and December 2025 at a single tertiary center. The primary outcome was first-attempt technical failure of EUS-HGS. Pre-puncture EUS images were reviewed to measure bile duct diameter at the intended puncture site, needle-duct angle, and hepatic parenchymal length. Independent predictors were identified using multivariable logistic regression, and a three-factor prediction model was developed. Discrimination, calibration, and internal validation with 2,000 bootstrap resamples were assessed. RESULTS: Among 453 attempted EUS-HGS procedures, first-attempt technical success was achieved in 400 (88.3%) and first-attempt technical failure occurred in 53 (11.7%). Smaller bile duct diameter (OR 0.282 per 1-mm increase; 95% CI 0.181-0.440), a more acute needle-duct angle (OR 0.632 per 10° increase; 95% CI 0.533-0.748), and longer hepatic parenchymal length (OR 1.144 per 1-mm increase; 95% CI 1.080-1.212) were independently associated with first-attempt technical failure. The combined three-factor model showed excellent apparent discrimination (AUC 0.932; 95% CI 0.897-0.961), with an optimism-corrected AUC of 0.927 after bootstrap validation. The optimal cutoff probability was 0.130, yielding 86.8% sensitivity and 85.5% specificity. Observed failure rates were 1.7% in the low-risk group, 9.0% in the intermediate-risk group, and 51.9% in the high-risk group. CONCLUSIONS: A three-factor model based on anatomical variables assessable on EUS before bile duct puncture showed excellent apparent discrimination and good calibration for predicting first-attempt technical failure during EUS-HGS. This internally validated model provides a preliminary framework for pre-puncture risk estimation; however, its clinical application remains hypothesis-generating and requires prospective multicenter external validation before implementation in clinical decision-making.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers