Foot (Edinburgh, Scotland)

Dorsal X-plate bridge fixation with implant retention for unstable Lisfranc injuries: Clinical and Radiological outcomes in 23 patients.

Sharan Vijayanand, J S R G Saran, S M Ajoy, A T Thippeswamy

Sanjay Gandhi Institute of Trauma and Orthopaedics, Bengaluru, Karnataka, India. · JSS Academy of Higher Education and Research, Mysuru, Karnataka, India. Electronic address: jsaran868@gmail.com.

Observational · n=23

Key points

From the paper's conclusion
  • In this small non-comparative series, dorsal X-plate bridge fixation with routine implant retention was feasible, with reduction maintained in most patients and one implant removal. Comparative studies with longer follow-up are needed before conclusions on safety or effectiveness relative to established constructs or elective removal can be drawn.

Abstract

BACKGROUND: Unstable Lisfranc injuries require accurate reduction and stable fixation, but the optimal construct and the need for routine implant removal remain debated. This study reports clinical and radiological outcomes of a four-hole X-shaped plate used as a dorsal bridge construct with routine implant retention. METHODS: This single-centre cohort included 23 consecutive patients with unstable Lisfranc injuries, operated between 2014 and 2023 and treated with a four-hole titanium X-plate fixed to the first and second metatarsals and the medial and intermediate cuneiforms. Twenty patients operated before ethics approval (May 2023) were identified retrospectively and three were enrolled prospectively. Reduction was graded by the C1-M2 diastasis on serial radiographs. Function was assessed with the Foot and Ankle Disability Index (FADI) and the American Orthopaedic Foot and Ankle Society (AOFAS) Midfoot score at 24 weeks, 12 months and 18 months, and implant status and complications were recorded to final follow-up (mean 47 months, minimum 18 months). RESULTS: A C1-M2 diastasis below 2 mm was achieved in 21 of 23 patients (91.3%) and maintained in all 21 at 18 months. Mean FADI improved from 82.7 at 24 weeks to 89.0 at 18 months and mean AOFAS from 78.0 to 84.2 (both p < 0.001). Implant-related complications occurred in three patients (13.0%): two asymptomatic screw back-outs and one symptomatic screw breakage requiring implant removal at 25.6 months (reoperation rate 4.3%). At final follow-up, 22 implants remained in situ and no infection, secondary arthrodesis or symptomatic post-traumatic arthritis had occurred. CONCLUSION: In this small non-comparative series, dorsal X-plate bridge fixation with routine implant retention was feasible, with reduction maintained in most patients and one implant removal. Comparative studies with longer follow-up are needed before conclusions on safety or effectiveness relative to established constructs or elective removal can be drawn. LEVEL OF EVIDENCE: IV, case series.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers