Accounting for Spatiotemporally Heterogeneous Measurement Error in Gridded PM2.5 Exposure Estimates: A Spatiotemporal Varying-Coefficient Calibration Approach.
Jianxiang Tang, Feng Hong, Xiuling Zhu, Wenqian Zeng, Jingru Xu, Mi Cheng, Shaoxiong Yang, Baimayangji,
West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China. · School of Public Health, the Key Laboratory of Environmental Pollution Monitoring and Disease Control, Ministry of Education, Guizhou Medical University, Guiyang, China.
Key points
From the paper's conclusion- These findings suggest that STVCCM, through its flexible representation of spatiotemporal calibration relationships, shows promise for addressing heterogeneous measurement error in PM2.5 epidemiologic studies.
Abstract
High-resolution gridded PM2.5 products enable large-scale epidemiological studies, but their use as residential exposure surrogates is subject to measurement error that may vary across space and time. Existing error calibration approaches often rely on predefined geographic and temporal strata, which may fail to capture local variation in measurement errors, thereby biasing health-effect estimates. We developed a spatiotemporal varying-coefficient calibration model (STVCCM) that used natural spline functions of spatial coordinates and calendar month to characterize spatiotemporal variation in the calibration relationship. The STVCCM was applied to the China Multi-Ethnic Cohort, and the exposure estimates obtained with the STVCCM were compared with those from uncalibrated models, models calibrated with standard regression (RC), and models calibrated with stratified regression (SRC). Measurement error, defined as the difference between gridded PM2.5 predictions and the corresponding monitoring observations, showed substantial spatiotemporal heterogeneity: mean absolute error (MAE) ranged from 3.5 to 14.7 μg/m3 across monitoring sites and was higher in January than in July (10.8 vs 4.7 μg/m3). At both the 10 μg/m3 and 1 SD scales, STVCCM yielded the highest numerical ORs for three of five outcomes. In simulation, STVCCM had the smallest observed absolute bias and root mean square error under the specified spatiotemporally heterogeneous error mechanism. These findings suggest that STVCCM, through its flexible representation of spatiotemporal calibration relationships, shows promise for addressing heterogeneous measurement error in PM2.5 epidemiologic studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Spatially autocorrelated and clustered associations between short-term exposure to PM2.5 and daily reported confirmed COVID-19 cases across the contiguous United States, 2020-2022.Frontiers in public health · 2026
- Spatially varying effect estimates of mediation in the presence of spatial auto-correlationmedRxiv · 2026
- Assessing satellite and reanalysis PM2.5 datasets for air quality applications in India.Environmental monitoring and assessment · 2026
- Assessment of the spatiotemporal evolution of PM2.5 and its health and economic effects in Central China based on spatial statistics and BenMAP.Environmental monitoring and assessment · 2026
- BRUCE (Bayesian Rio Urban Climate Estimator): spatiotemporal interpolation of air temperature from heterogeneous sensor networks for operational heat monitoringarXiv · 2026
- Calibration Model for Purple Air monitored PM2.5 across the United States.Environmental pollution (Barking, Essex : 1987) · 2026