Assessing satellite and reanalysis PM2.5 datasets for air quality applications in India.
S Vaishnavi, Jyoti Bhate, P R Sinha
National Atmospheric Research Laboratory, Department of Space, Government of India, Gadanki, Andhra Pradesh, India, 517112. · National Atmospheric Research Laboratory, Department of Space, Government of India, Gadanki, Andhra Pradesh, India, 517112. jyoti@narl.gov.in.
Key points
From the paper's conclusion- Overall, the results show that PM2.5 product performance is strongly dependent on product type, region, timescale, and application, highlighting the need for careful validation and appropriate bias correction before these datasets are used for air-quality assessment over India.
Abstract
Spatially continuous PM2.5 products are widely used for air-quality and exposure assessment in India, but differences in spatial resolution, monitor density, and product construction can complicate direct inter-comparison. This study evaluates CAMS EAC4, MERRA-2, and satellite-derived SatPM2.5 V6.GL.02.04 against quality-controlled Central Pollution Control Board (CPCB) observations over India during 2022-2023. The primary inter-product comparison was performed on common 0.75° CAMS grid: 248 stations retained for monthly analysis and 249 for daily analysis were aggregated within 101 CAMS cells, while MERRA-2 and SatPM2.5 were conservatively area-averaged to the same grid. On the monthly common grid sample, CPCB averaged 49.38 µg m⁻3. SatPM2.5 showed the smallest overall error (MB = -2.07 µg m⁻3; RMSE = 25.34 µg m⁻3; r = 0.708; IOA = 0.827), MERRA-2 moderately underestimated PM2.5 (MB = -6.83 µg m⁻3; RMSE = 27.58 µg m⁻3), and CAMS retained a large positive bias (MB = +56.15 µg m⁻3; RMSE = 79.39 µg m⁻3). Daily RMSE was 85.16 µg m⁻3 for CAMS and 35.12 µg m⁻3 for MERRA-2. Bias correction was then tested using a spatiotemporal holdout in which each test CAMS cell was excluded from training and correction parameters were estimated from the opposite year, same region, and same calendar month. Multiplicative correction reduced CAMS daily RMSE from 84.53 to 33.23 µg m⁻3 and increased IOA from 0.580 to 0.781; additive correction reduced MERRA-2 daily RMSE from 35.06 to 33.54 µg m⁻3 and increased IOA from 0.700 to 0.770. For the 60 µg m⁻3 daily exceedance threshold, observed exceedances occurred on 27.0% of common-grid cell-days, compared with 64.6% for raw CAMS and 20.0% for raw MERRA-2. Region-specific correction parameters provided additional improvements. Overall, the results show that PM2.5 product performance is strongly dependent on product type, region, timescale, and application, highlighting the need for careful validation and appropriate bias correction before these datasets are used for air-quality assessment over India.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improving Satellite-Reanalysis Sulfate Aerosol Estimates over India Using Ground Measurements.Environmental pollution (Barking, Essex : 1987) · 2026
- Long-term spatiotemporal assessment of PM₂.₅ in a semi-urban region of Bangladesh using CAMS and MERRA-2 reanalysis dataScientific Reports · 2026
- Accounting for Spatiotemporally Heterogeneous Measurement Error in Gridded PM2.5 Exposure Estimates: A Spatiotemporal Varying-Coefficient Calibration Approach.Environmental pollution (Barking, Essex : 1987) · 2026
- Integrated multi-scale assessment of particulate matter in coastal environments: long-term analysis, mobile monitoring, and spatial prediction techniquesScientific Reports · 2026
- India Spatio-Temporal Air Quality Dataset (2023–2025): Monthly Integration of Sentinel-5P, ERA5-Land, and CPCB Monitoring StationsMendeley Data · 2026
- Integration of Satellite and Ground-Based Data for High-Resolution PM2.5 Assessment and Hotspot Identification Using Machine LearningACS ES&T Air · 2026