European journal of radiology

Performance gaps across training, internal testing, and external testing in radiomics models: A meta-research study.

Burak Kocak, Ozge Coskun, Fadime Kose, Tuba Banaz, Muhammed Faruk Kazanbas, Erdem Altan, Ali Keles

Department of Radiology, Basaksehir Cam and Sakura City Hospital, Istanbul, Türkiye. Electronic address: drburakkocak@gmail.com. · Department of Radiology, Basaksehir Cam and Sakura City Hospital, Istanbul, Türkiye.

Observational

Key points

From the paper's conclusion
  • In this randomized, validation-enriched sample of recent PubMed-indexed radiomics studies, radiomics model discrimination declined across evaluation stages, with the largest loss between training and external testing. The aggregate pattern remained evident after precision weighting but was often inconclusive within individual studies. Although methodologically valuable, the presence of external validation alone did not establish preservation of performance relative to development.

Abstract

OBJECTIVE: To quantify changes in radiomics model discrimination across training, internal testing, and external testing and assess whether external validation indicates preservation of performance. METHODS: This protocol-guided meta-research study included 2023-2025 radiomics studies reporting training, internal-test, and external-test area under the receiver operating characteristic curve (AUC) values for binary models. PubMed/MEDLINE records were selected by randomized quota sampling. Within-study training-to-internal, training-to-external, and internal-to-external AUC gaps were calculated. Equal-weight Wilcoxon signed-rank tests were primary analyses, with paired t tests as secondary analyses. Point estimates defined gap magnitude, and reconstructed approximate 95% confidence intervals described study-level uncertainty. Post hoc inverse-variance random-effects analyses assessed robustness to precision. Additional post hoc sensitivity analyses assessed robustness to external-validation design and external-test data use in harmonization. Exploratory meta-regressions examined associations between training sample size and performance gaps. RESULTS: Forty-nine studies were included. Median AUC declined from 0.920 in training cohorts to 0.882 in internal-test cohorts and 0.860 in external-test cohorts. The training-to-external gap was largest: median, 0.060 (interquartile range, 0.030-0.107); mean, 0.063 (standard deviation, 0.054). All three gaps differed from zero. At least moderate loss occurred in 18 studies (36.7%) for training-to-internal testing, 27 studies (55.1%) for training-to-external testing, and 10 studies (20.4%) for internal-to-external testing. Precision-weighted pooled differences were 0.034 (95% confidence interval, 0.023-0.045), 0.061 (0.047-0.076), and 0.029 (0.018-0.040), respectively, closely matching unweighted results. Most reconstructed study-level gap confidence intervals included zero, including 36 of 49 (73.5%) training-to-external intervals. Despite the aggregate pattern of performance loss, 47 of 49 studies (95.9%) reached positive or cautiously positive conclusions. CONCLUSION: In this randomized, validation-enriched sample of recent PubMed-indexed radiomics studies, radiomics model discrimination declined across evaluation stages, with the largest loss between training and external testing. The aggregate pattern remained evident after precision weighting but was often inconclusive within individual studies. Although methodologically valuable, the presence of external validation alone did not establish preservation of performance relative to development.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers