European radiology

Lifting the radiomics performance ceiling: how preprocessing leakage amplifies model multiplicity.

Clemente García-Hidalgo, José Antonio Consentino Hernández, José Vicente Cayuela Espí

Radiology Department, Hospital Universitario Morales Meseguer, Murcia, Spain. clemente292@gmail.com. · Radiology Department, Hospital Universitario Morales Meseguer, Murcia, Spain.

Computational · n=147

Key points

From the paper's conclusion
  • The three sources compound; leakage amplifies model multiplicity by inflating the performance ceiling.

Abstract

OBJECTIVES: To jointly quantify and causally link preprocessing leakage, analytical flexibility and the Rashomon effect in radiomics-based clinical prediction models. MATERIALS AND METHODS: Retrospective methodological (specification-curve) analysis of 50 de-identified binary-classification datasets in radMLBench (multicentre; 13 anatomical sites; CT, MRI, PET/CT; median 147 patients per dataset, range 51-969); prediction-model reporting followed CLAIM 2.0 and TRIPOD + AI 2024. We enumerated an analytical multiverse of 456 pipeline specifications (3 scalers × 2 correlation filters × 19 feature selectors × 4 classifiers), each evaluated against the dataset label by 5-fold cross-validation × 10 repetitions. Feature-level preprocessing leakage was assessed by paired global-versus-nested comparison for the synthetic minority oversampling technique (SMOTE), normalisation, correlation filtering and principal component analysis (PCA), pooled by DerSimonian-Laird meta-analysis. Within-subjects causal mediation (43 datasets) tested whether inflation of the best area under the receiver operating characteristic curve (AUC) explains leakage-induced Rashomon-set expansion. RESULTS: Across the 50 datasets, SMOTE leakage inflated AUC by a pooled 0.09 (95% confidence interval (CI): 0.07, 0.11; p < 0.001), exceeding 0.05 in 64%. Pipeline choice shifted AUC by 0.30, classifier dominating (eta-squared = 0.21). At ε = 5%, near-optimal pipelines disagreed on 20-30% of patient classifications (Fleiss kappa = 0.58) and shared < 30% of top features. SMOTE leakage quadrupled the Rashomon set (0.06 to 0.23; p < 0.001); 79% mediated by best-AUC inflation. Radiomics showed 4.8× wider vibration of effects (VoE) but 13× smaller Rashomon ratios than eight tabular benchmarks (both p < 0.001). CONCLUSION: The three sources compound; leakage amplifies model multiplicity by inflating the performance ceiling. KEY POINTS: Question Whether preprocessing leakage, analytical flexibility and the Rashomon effect jointly compromise the reproducibility of radiomics-based clinical prediction models has not been quantified. Findings Across 50 radiomics datasets, SMOTE leakage inflated AUC by 0.09 and quadrupled the Rashomon set, with 79% causally mediated by best-AUC inflation. Clinical relevance Radiomics-derived clinical prediction models routinely disagree on 20-30% of patients while appearing equally near-optimal. The released three-layer audit tool quantifies this risk per study and should precede any clinical deployment claim.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers