European journal of obstetrics, gynecology, and reproductive biology

Management of presacral hemorrhage during laparoscopic sacrocolpopexy using an autologous round ligament patch: a video case report.

Cesar Sandoval Sepulveda, Ignacia Regonesi Ramirez, Rodrigo Guzman Rojas, Daniela Espinola Marin, Gabriel Vallejos Penaloza

Departamento de Ginecologia y Obstetricia, Facultad de Medicina, Clinica Alemana-Universidad del Desarrollo, Santiago, Chile. · Departamento de Ginecologia y Obstetricia, Facultad de Medicina, Clinica Alemana-Universidad del Desarrollo, Santiago, Chile; Departamento de Ginecologia y Obstetricia, Hospital Padre Hurtado, Santiago, Chile.

Case report

Key points

From the paper's conclusion
  • The use of an autologous round ligament fragment as a tissue interface for bipolar coagulation may represent a feasible adjunct for controlling difficult presacral bleeding during minimally invasive pelvic surgery. This approach is immediately available and cost-neutral; however, its mechanism and generalizability remain uncertain. Further experience is needed to define its role relative to established hemostatic techniques.

Abstract

BACKGROUND: Presacral hemorrhage during laparoscopic sacrocolpopexy is an uncommon but potentially serious complication that can be difficult to control using standard techniques. Autologous tissue may serve as a readily available adjunct in challenging intraoperative bleeding scenarios. CASE PRESENTATION: A 66-year-old woman with symptomatic stage III pelvic organ prolapse underwent laparoscopic sacrocolpopexy. During suture placement at the sacral promontory, brisk presacral bleeding occurred that was not adequately controlled with bipolar coagulation and compression. A small fragment of the round ligament was harvested laparoscopically and applied directly over the bleeding site. Bipolar energy was delivered through the tissue, resulting in cessation of bleeding. The procedure was completed without conversion, transfusion, or use of commercial hemostatic agents. Postoperative recovery was uncomplicated, and no recurrent bleeding or prolapse was observed at 6-month follow-up. CONCLUSION: The use of an autologous round ligament fragment as a tissue interface for bipolar coagulation may represent a feasible adjunct for controlling difficult presacral bleeding during minimally invasive pelvic surgery. This approach is immediately available and cost-neutral; however, its mechanism and generalizability remain uncertain. Further experience is needed to define its role relative to established hemostatic techniques.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers