International urogynecology journal

Robot-Assisted Sacrohysteropexy Using Autologous Fascia Lata for the Treatment of Uterine Prolapse (SAFUP): Initial Experience and Outcomes.

Chin Yong, Haylee Boyens, Dean McKenzie, Pav Nanayakkara

Epworth Freemasons Hospital, Suite 6.3, Level 6, 124 Grey Street, East Melbourne, Victoria, 3002, Australia. drchinyong@gmail.com. · Epworth Freemasons Hospital, Suite 6.3, Level 6, 124 Grey Street, East Melbourne, Victoria, 3002, Australia.

Key points

From the paper's conclusion
  • Robot-assisted AFL SHP appears feasible, with promising short-term anatomical and patient-reported outcomes and low donor-site morbidity. Larger comparative studies with longer-term follow-up are required.

Abstract

INTRODUCTION AND HYPOTHESIS: Sacrohysteropexy using synthetic mesh is an established uterine-preserving treatment for uterine prolapse; however, concerns regarding mesh-related complications have increased interest in mesh-free alternatives. We hypothesised that robot-assisted SHP using autologous fascia lata (AFL) would provide effective apical support with acceptable donor-site morbidity. This study describes the surgical technique and reports short-term anatomical, functional, and patient-reported outcomes. METHODS: This combined retrospective and prospective single-centre study included consecutive women undergoing robot-assisted AFL sacrohysteropexy for symptomatic uterine prolapse between August 2022 and November 2024. A 12 cm × 3 cm AFL graft was harvested through a single lateral thigh incision and implanted in a hockey stick configuration. The primary outcome was POP-Q point C at 12 months. Secondary outcomes included objective success (POP-Q point C ≥2 cm above the hymen during maximal Valsalva), full POP-Q measurements, pelvic floor questionnaire scores, patient satisfaction, pain scores, and donor-site morbidity. RESULTS: Twenty patients completed 12-month follow-up. Mean POP-Q point C improved from +3.25 cm to -7.25 cm at 12 months (mean change of 10.5 cm, 95% CI 8.97-12.03). Objective success was achieved in all patients at both 6 and 12 months. Mean prolapse symptom scores improved from 8.05 at baseline to 0.25 at 12-months (difference 7.8, 95% CI 5.80-9.80). Satisfaction remained high at both time points. Donor-site morbidity was mild and self-limiting, complete resolution by 12 months. CONCLUSIONS: Robot-assisted AFL SHP appears feasible, with promising short-term anatomical and patient-reported outcomes and low donor-site morbidity. Larger comparative studies with longer-term follow-up are required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers