European journal of obstetrics, gynecology, and reproductive biology

Reference ranges of the fetal ductus arteriosus area by Three-Dimensional ultrasonography.

Christiane Simioni, Alberto Borges Peixoto, Gustavo Yano Callado, André Souza Malho, Maria Elisa Martini Albrecht, Antonio Braga, Nathalie Jeanne Bravo-Valenzuela, Edward Araujo Júnior

Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo, Brazil. · Gynecology and Obstetrics Service, Mario Palmério University Hospital - University of Uberaba (UNIUBE), Uberaba - MG, Brazil; Department of Obstetrics and Gynecology, Federal University of Triângulo Mineiro (UFTM), Uberaba - MG, Brazil.

Observational

Key points

From the paper's conclusion
  • Reference curves for the fetal DA area by 3D ultrasonography with STIC in the multiplanar and rendering modes were determined and showed a strong correlation with gestational age. These measurements showed good reliability but wide limits of agreement; the two modes are not interchangeable, and their clinical usefulness remains to be established.

Abstract

OBJECTIVE: To determine reference values for the fetal ductus arteriosus (DA) area using three-dimensional (3D) ultrasonography with spatio-temporal image correlation (STIC) in the rendering and multiplanar modes. METHODS: A prospective cross-sectional study was conducted with 322 cardiac volumes from normal fetuses between 20 and 33 + 6 weeks. DA area measurements were performed in the multiplanar (sagittal B-plane) and rendering modes. Polynomial regression models were fitted and assessed using the coefficient of determination (R2). Reproducibility was assessed by the concordance correlation coefficient (CCC) and Bland-Altman plots, and agreement between modes by Bland-Altman analysis and least products regression. RESULTS: Patient age ranged from 18 to 45 years, with a median of 29.0 years. The median gestational age at the time of the ultrasound examination was 26.6 weeks (20.0-33.9 weeks). A linear relationship and a significant strong positive correlation were observed between gestational age and DA area measurements in the multiplanar and rendering modes (R2 = 0.54 and 0.53, respectively). Mean DA areas in the multiplanar and rendering modes ranged from 0.06 to 0.32 cm2 and 0.07 to 0.37 cm2, respectively. Intra- and interobserver reliability was good (CCC ≥ 0.72), but relative limits of agreement were wide. The rendering mode yielded larger areas (mean difference -0.028 cm2). CONCLUSION: Reference curves for the fetal DA area by 3D ultrasonography with STIC in the multiplanar and rendering modes were determined and showed a strong correlation with gestational age. These measurements showed good reliability but wide limits of agreement; the two modes are not interchangeable, and their clinical usefulness remains to be established.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers