Reference Ranges for Fetal Ventricular Global Longitudinal Strain (GLS) Using Bidimensional Speckle-Tracking Echocardiography: A Systematic Review.
Danielle Bittencourt Sodré Barmpas, Maria de Fátima Monteiro Pereira Leite, Saint Clair Gomes Junior, Karla G Camacho, Maria Virginia M Peixoto, Heron Werner, Renato Augusto Moreira de Sá
Fernandes Figueira National Institute of Women's, Children's and Adolescents' Health (IFF/Fiocruz), Rio de Janeiro CEP 22250-020, Brazil. · Department of Fetal Medicine, Biodesign Laboratory DASA/PUC, Campus Gávea, Rio de Janeiro CEP 22451-900, Brazil.
Key points
From the paper's conclusion- Background/Objectives: The primary objective was to assess reference intervals for fetal Global Longitudinal Strain (GLS) using bidimensional speckle-tracking echocardiography (2D-STE), including only prospective studies specifically designed for this purpose.
Abstract
Background/Objectives: The primary objective was to assess reference intervals for fetal Global Longitudinal Strain (GLS) using bidimensional speckle-tracking echocardiography (2D-STE), including only prospective studies specifically designed for this purpose. An additional objective was to evaluate studies' methodological quality and reproducibility. Methods: This is a systematic review registered at PROSPERO (CRD420251038889). Five electronic databases (Web of Science, Scopus, MEDLINE/PubMed, EMBASE and LILACS) were searched, from inception to May 2025. Prospective studies specifically designed to establish 2D-STE GLS reference intervals in low-risk singleton pregnancies with normal fetuses were included. Data were independently extracted by two reviewers. Risk of bias was assessed using an adapted tool, including study design and statistical and reporting methods. Results: After the initial identification of 187 records, nine studies published between 2012 and 2025 were included. There was marked heterogeneity among the studies. Four articles achieved high-quality scores (>70%) and three of them reported similar left ventricular (LV) GLS at 24 weeks (-22%). Right ventricular absolute GLS values were slightly lower than LV numbers. Regression models for both ventricles showed GLS absolute values decreased with gestation across studies. The 2D-STE algorithm (endocardial versus myocardial) was the main source of discrepancy between studies. Conclusions: High-quality prospective studies show a consistent pattern of biventricular GLS variation with gestational age. However, technical heterogeneity, lack of standardization, operator subjectivity and vendor-specific algorithm differences currently limit the applicability of the method. Multicentric studies with large sample sizes, standardized protocols and artificial intelligence-assisted tools are needed to consolidate this technique.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reproducibility of fetal global longitudinal strain measured with speckle tracking echocardiography using a fixed cardiac cyclePLoS ONE · 2026
- Qualitätssicherung und Reproduzierbarkeit der fetalen 2D-Speckle-Tracking-EchokardiographieDie Gynäkologie · 2026
- Maternal Age and Fetal Ventricular Function at 20–22 Weeks: Assessment of Left and Right Ventricular Global Longitudinal Strain in 1345 Uncomplicated Singleton PregnanciesChildren · 2026
- Inter-vendor agreement and test-retest reproducibility of right ventricular and left atrial strain measurements using two-dimensional speckle-tracking echocardiographyEuropean Heart Journal · 2026
- Persistent subclinical myocardial dysfunction among infants with Fetal growth restriction at one year of age.Pediatric research · 2026
- Left ventricular strain measured by feature-tracking cardiac magnetic resonance imaging and 2D speckle-tracking echocardiography in chronic ischemic heart disease: an intermodality agreement studyJournal of Cardiovascular Imaging · 2026