Global dose entropy as a surrogate of geometric robustness in radiotherapy treatment planning: A multi-site study of clinical plan.
Sandeep Singh, Supratik Sen, Abhay Kumar Singh, Dipesh, Soniya Pal, Mahipal, Vikram, Manindra Bhushan
Department of Radiation Oncology, Amrita School of Medicine, Amrita Vishwa Vidyapeetham, Faridabad, Haryana, India; Department of Physics, GLA University, Mathura, Uttar Pradesh, India. Electronic address: sandeep.singh82a@gmail.com. · Department of Radiation Oncology, Dr. B. Borooah Cancer Institute, Guwahati, Assam, India. Electronic address: supratiksem494@gmail.com.
Key points
From the paper's conclusion- Entropy-derived metrics, particularly Global Dose Entropy, demonstrated stronger associations with geometric robustness than conventional descriptors and may provide a framework for robustness-informed radiotherapy plan evaluation.
Abstract
PURPOSE: To investigate whether entropy-derived complexity metrics are associated with radiotherapy plan robustness and compare their performance with conventional complexity descriptors across multiple disease sites. METHODS: A retrospective analysis was performed on 140 VMAT treatment plans comprising brain (n = 50), head-and-neck (n = 50), and pelvic (n = 40) cases. Global Dose Entropy and Spatial Dose Disorder Index (SDDI) were calculated from three-dimensional dose distributions and compared with aperture entropy, aperture variability, mean dose gradient, total monitor units (MU), and Modulation Complexity Score (MCS). Robustness was evaluated using geometric perturbation analysis, with dosimetric deviations quantified using worst |ΔPTV D95|, worst |ΔPTV D98|, worst |ΔOAR D2|, worst |ΔOAR Max|, and worst |ΔOAR Mean|. Associations were assessed using Spearman correlation analysis. RESULTS: Global Dose Entropy showed strongest correlations with robustness endpoints (ρ = 0.503-0.581, p < 0.001). SDDI showed moderate correlations (ρ = 0.351-0.459, p < 0.001), whereas conventional metrics showed weaker associations. MCS demonstrated moderate inverse correlations (ρ = -0.330 to -0.420). Non-robust plans exhibited higher Global Dose Entropy than robust plans (4.63 ± 0.53 vs 3.67 ± 0.59; p < 0.001). These findings indicate that dose-distribution complexity captures information related to perturbation sensitivity beyond delivery-based parameters and supports further investigation of entropy-based approaches for robustness assessment across diverse clinical treatment planning environments workflows. CONCLUSIONS: Entropy-derived metrics, particularly Global Dose Entropy, demonstrated stronger associations with geometric robustness than conventional descriptors and may provide a framework for robustness-informed radiotherapy plan evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of Dose to Medium and Dose to Water with the Acuros XB Algorithm for SABR: Clinical and Phantom-Based Observations.Biomedical physics & engineering express · 2026
- Evaluating synthetic CT from deformable registration in directed adaptive radiotherapy for head and neck cancer.Journal of applied clinical medical physics · 2026
- A Novel Medical Conformity Index (MCI) Integrating Spatial Distance and Target Volume Weighting for Enhanced Radiotherapy Plan Evaluation.Technology in cancer research & treatment · 2026
- Task-dependent predictability of gamma passing rates in stereotactic body radiation therapy using UCoMX plan-complexity features: a patient-group-aware machine learning benchmarkFrontiers in Oncology · 2026
- Machine learning prediction of electronic-portal-imaging-device-based in vivo dosimetry results using plan complexity metrics, machine output and gamma passing rate: a feasibility study.Physical and engineering sciences in medicine · 2026
- Zernike morphological description of dose distributions in radiotherapy and radiosurgery.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026