An evaluation of Geant4-DNA early radiochemical yields.
A Paillet, H N Tran, S Zein, S Fattori, S Okada, J R Ramos-Méndez, L T Anh, V Ivantchenko,
Univ. Bordeaux, CNRS, LP2I Bordeaux, UMR 5797, F-33170 Gradignan, France. Electronic address: paillet@lp2ib.in2p3.fr. · Univ. Bordeaux, CNRS, LP2I Bordeaux, UMR 5797, F-33170 Gradignan, France.
Key points
From the paper's conclusion- It remains difficult to clearly favor one physics or chemistry model over another because of the dispersion of experimental radiolysis data at short times. We recommend continuing experimental radiolysis measurements to help benchmark simulations.
Abstract
PURPOSE: To evaluate Geant4-DNA for the simulation of radiochemical yields in liquid water up to 1µs after irradiation, for incident electrons, protons and alpha particles beams in the keV-MeV kinetic energy range. METHODS: Simulations of radiochemical yields are presented as a function of time for electrons and as a function of the beam parameter MZ2/E for protons and alpha particles. They use the "chem6" and "UHDR" reference examples available in Geant4 version 11.4.0 (December 2025). The impact of physics, chemistry and time step models is investigated, and quantitatively compared to experimental data. RESULTS: The option 4 physics constructor shows better plausibility for the simulation of G-values versus time and G-values versus MZ2/E. The option 3 chemistry constructor shows a global better agreement with experimental data. The micro/mesoscopic "UHDR" example is able to reproduce "chem6" results for simulations up to 1µs. CONCLUSION: It remains difficult to clearly favor one physics or chemistry model over another because of the dispersion of experimental radiolysis data at short times. We recommend continuing experimental radiolysis measurements to help benchmark simulations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of a new set of Geant4-DNA Physics models for the simulation of electron track structures in liquid water up to 10 MeV.Medical physics · 2026
- A concentration-source-driven and GPU-accelerated standalone radiochemistry framework for continuous water radiolysis and pulse-structure simulation.Physics in medicine and biology · 2026
- Geant4-DNA Simulation of the Oxygen Depletion Coefficient and the Relative Change in OER in Proton-Irradiated Oxygenated Water.International journal of molecular sciences · 2026
- Physicochemical modeling of electron FLASH to identify the roles of oxygen, aqueous electrons and causal radical recombination effects underlying them.Physics in medicine and biology · 2026
- From voxel S-values to DNA damage: Multiscale simulation of β- emitters with Geant4 and Geant4-DNA.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Resolving the contradiction between simulation and experimental results of using gold nanoparticles in proton therapyScientific Reports · 2026