Abstract

The monitoring of surface contamination is a key element of radiological protection programmes in facilities handling unsealed radioactive sources, such as biological, clinical and radiochemical laboratories. For low-energy β-emitters such as tritium (³H) and carbon-14 (¹⁴C), direct detection is generally ineffective, and smear sampling followed by liquid scintillation counting (LSC) represents the standard approach. However, the swab material may affect the counting process and lead to activity underestimation, making the choice of a suitable substrate a relevant issue for routine monitoring. In the present work, five readily available laboratory materials were comparatively assessed as swab substrates: polystyrene, glass fibre, nylon, polycarbonate and polytetrafluoroethylene (PTFE). To isolate the effect of the substrate from sampling uncertainties, known activities of ³H and ¹ ⁴C were deposited directly onto each material and measured using the Triple-to-Double Coincidence Ratio (TDCR) method. Polystyrene, which fully dissolves in the scintillation cocktail, yielded recoveries close to 100% for both radionuclides, although its poor mechanical resistance limits its use for wiping. Glass fibre, nylon and PTFE also showed recoveries close to 100% for ³H, whereas for ¹ ⁴C geometric shielding reduced recovery to approximately 70% and 50% for unfolded and folded filters, respectively. Polycarbonate caused colour quenching, with ³H losses of 75-100%. These findings demonstrate that reliable smear tests can be performed with standard laboratory consumables, without the need for specialised products, provided that the swab material is selected on a radionuclide-specific basis.

Read the paper