Comparison of MALDI-TOF MS and VITEK 2 performance in the identification of brucella strains isolated from blood culture bottles; retrospective evaluation of antibiotic resistance profiles, clinical manifestations, and serological follow-up.
Merve Ertürk Melez, Pınar Sağıroğlu, Sıtkı Özgür Altop, Mustafa Altay Atalay, Orhan Yıldız
Department of Medical Microbiology, Faculty of Medicine, Erciyes University, Kayseri, Turkey. Electronic address: merveerturk@erciyes.edu.tr. · Department of Medical Microbiology, Faculty of Medicine, Erciyes University, Kayseri, Turkey.
Key points
From the paper's conclusion- The MALDI Biotyper Sirius provides superior diagnostic speed and biosafety via reliable species-level identification using routine spectral libraries. Automated phenotypic misidentifications (e.g., R. gilardii) represent critical biohazards that warrant urgent MALDI-TOF MS verification. High in vitro resistance to SXT highlights potential disk diffusion overestimation in fastidious organisms, emphasizing the necessity of broth microdilution MIC confirmation before precluding vital oral treatment options.
Abstract
INTRODUCTION AND OBJECTIVES: Brucella species cause severe zoonotic infections with an exceptionally high risk of laboratory-acquired transmission. We systematically evaluated and compared the identification performances of two contemporary MALDI-TOF MS platforms and the VITEK 2 automated system, analyzed serial standard tube agglutination (STA) titer kinetics, and determined in vitro antimicrobial susceptibility profiles of clinical blood culture isolates. MATERIALS AND METHODS: Twenty-five culture-confirmed Brucella isolates recovered from peripheral blood culture bottles between 2019 and 2025 were evaluated using the MALDI Biotyper Sirius (routine MBT Compass library), VITEK MS Prime (IVD database v3.3), and VITEK 2 GN automated identification cards. All sample manipulation and ethanol/formic acid extraction were performed inside a certified Class II Biosafety Cabinet ensuring complete inactivation prior to mass spectrometry. Antimicrobial susceptibility was determined by the disk diffusion method on Mueller-Hinton Fastidious (MH-F) agar according to EUCAST (v. 16.0) guidelines. Clinical data and serial STA titers were retrospectively analyzed. RESULTS: The MALDI Biotyper Sirius accurately identified all 25 isolates (100%) at the species level as Brucella melitensis, whereas the VITEK MS Prime identified all (100%) at the genus level (Brucella spp.). In contrast, the VITEK 2 GN automated system demonstrated markedly poor diagnostic utility, correctly identifying 92% (23/25) of isolates, failing to identify one isolate ('unidentified'), and misidentifying another blood culture isolate as Roseomonas gilardii. A statistically significant decrease in Wright tube agglutination titers was observed following treatment (median initial titer 1:320 [IQR, 1:160-1:640] vs. median final titer 1:80 [IQR, 1:40-1:160]; p = 0.007). Serological reductions did not differ significantly across therapeutic regimens (p = 0.3219). All isolates (100%) were fully susceptible to rifampin, doxycycline and gentamicin. Resistance rates to trimethoprim-sulfamethoxazole (SXT) and ciprofloxacin were 40% (10/25) and 24% (6/25), respectively. Favorable clinical cure without relapse was achieved in patients receiving SXT-containing regimens despite in vitro resistance. CONCLUSIONS: The MALDI Biotyper Sirius provides superior diagnostic speed and biosafety via reliable species-level identification using routine spectral libraries. Automated phenotypic misidentifications (e.g., R. gilardii) represent critical biohazards that warrant urgent MALDI-TOF MS verification. High in vitro resistance to SXT highlights potential disk diffusion overestimation in fastidious organisms, emphasizing the necessity of broth microdilution MIC confirmation before precluding vital oral treatment options.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid identification and antimicrobial susceptibility testing of pathogenic microorganisms from positive blood cultures.PloS one · 2026
- Hands-on time, time to result, and inter-device concordance: a prospective real-life comparison of three MALDI-TOF MS systems in the routine laboratoryFrontiers in Cellular and Infection Microbiology · 2026
- Validation of EUCAST 2026 breakpoints for Brucella species using routine laboratory methods: A comprehensive French National Reference Centre study.PLoS neglected tropical diseases · 2026
- Pathogen identification and resistance gene expression tests using ASTar remnant bacterial suspension in gram-negative contrived positive blood cultures.Microbiology spectrum · 2026
- Performance comparison and clinical validation of two rapid direct identification and antimicrobial susceptibility testing approaches for pathogens isolated from positive blood cultures in children.Frontiers in cellular and infection microbiology · 2026
- A comparative analysis of performance and time-to-result for VITEK REVEAL versus MicroScan during antimicrobial susceptibility testing for gram-negative bacteremia.Microbiology spectrum · 2026