Multi-cohort external validation of personalized uncertainty-aware short-term glucose forecasting in type 1 diabetes.
Hadjer Diab, Meryem Saidi, Hicham Talib Betaouaf, Djamel Mekkaoui
Laboratory of Biomedical Engineering, University of Abou Bekr Belkaid, Tlemcen, Algeria. Electronic address: hadjer.diab@univ-tlemcen.dz. · Laboratory of Biomedical Engineering, University of Abou Bekr Belkaid, Tlemcen, Algeria; Higher School of Management, Tlemcen, BP 230, Chetouane 13000, Tlemcen, Algeria. Electronic address: m.saidi@esm-tlemcen.dz.
Key points
From the paper's conclusion- A brief, one-time individualized profile supported clinically acceptable and uncertainty-aware glucose forecasting across previously unseen T1D populations without patient-specific retraining, supporting the feasibility and cross-cohort robustness of this low-burden personalization strategy.
Abstract
AIMS: To determine whether a personalized, uncertainty-aware glucose-forecasting tool provides clinically acceptable 30-minute glucose forecasts in people with type-1-diabetes (T1D) when applied to populations it was not trained on, without patient-specific retraining. METHODS: This retrospective study included 412 participants with T1D from five independent cohorts. A fixed individualized profile from each participant's initial valid 24 h was combined with 60 min of recent CGM/insulin history to generate 30-minute forecasts. Five-fold leave-one-cohort-out-validation withheld each cohort entirely from model development. Clinical acceptability (Clarke-Error-Grid), prediction-interval coverage, participant-level accuracy (MAE/RMSE), and non-personalized comparator were assessed. RESULTS: Across held-out cohorts, 93.9-98.3% of forecasts fell in clinically acceptable adapted Clarke Error Grid Zones A + B (mean 96.8%), and dangerous Zone-E errors were rare (0.000-0.014%). Mean 90% prediction-interval coverage was 90.04%. Participant-level MAE ranged between (15.5-21.65 mg/dL) and RMSE (20.6 to 29.0 mg/dL). The cohort with the lowest numeric error did not have the most favorable clinical-risk profile, and the personalized model achieved lower participant-macro MAE and RMSE than the matched non-personalized one across all five held-out cohorts. CONCLUSIONS: A brief, one-time individualized profile supported clinically acceptable and uncertainty-aware glucose forecasting across previously unseen T1D populations without patient-specific retraining, supporting the feasibility and cross-cohort robustness of this low-burden personalization strategy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- FairGlucose: A CGM Fairness Benchmark Reveals Subgroup Disparities Hidden in Population-Level ValidationarXiv · 2026
- Machine Learning Models for Glycemic Prediction in Type 1 and Type 2 Diabetes: Systematic Review and Meta-Analysis.Journal of medical Internet research · 2026
- Narrowing the A1c gap: Personalized modeling of HbA1c– continuous glucose monitor discordance in type 1 diabetesPLOS Digital Health · 2026
- Forecasting accuracy is not enough: safety-oriented evaluation of neural digital twins prior to in-silico insulin and carbohydrate intervention in type 1 diabetes.Frontiers in endocrinology · 2026
- Review of machine learning models in short- and long-term glucose forecasting and hypoglycemia classificationInformatics in Medicine Unlocked · 2025
- Glycemic-aware and architecture-agnostic training framework for blood glucose forecasting in type 1 diabetesBMC Artificial Intelligence · 2026