Dental materials : official publication of the Academy of Dental Materials

Spatio-temporal optical and thermal monitoring reveals light-source- and photoinitiator-dependent cure heterogeneity in experimental resin-based composites.

Mohammed A Hadis, Adrian C Shortall, William M Palin

University of Birmingham, UK. Electronic address: m.hadis@bham.ac.uk. · University of Birmingham, UK.

Key points

From the paper's conclusion
  • This study highlights centrally measured transmission, temperature and DC do not reflect local effects, and the importance of spectral and spatial beam irradiance uniformity for curing resin-based materials, as well as appropriately matching LCU output with PIs. An ideal approach to curing large restorations require homogenous beam profiles (power, wavelength and temperature) with appropriate irradiance and exposure times in combination with highly efficient PI systems, appropriate concentrations and broad absorption ranges.

Abstract

OBJECTIVE: To assess the influence of beam profile and photoinitiator (PI) chemistry (type and concentration) on dynamic beam transmission and temperature change, and degree of conversion (DC) in experimental resin-based composites (RBC). MATERIALS AND METHODS: Filled RBCs were formulated with 3:2 bisGMA:TEGDMA. Materials contained equimolar concentrations of CQ-only, TPO-only and CQ+TPO. An additional group contained half the concentration of CQ only + TPO only materials. Calibrated spectrometer-based devices were used to determine spectral power, irradiance, curing time and energy transmitted by light curing units (LCUs). Specimens were fabricated (12 mm diameter, 1.5 mm thick) and cured using a Bluephase Style or G4 light curing unit (LCU) for 3 s or 10 s. The LCUs were used with homogenising tips (Style and G4) or a non-homogenising tip (Style only). A beam profiler was used to assess transmission through materials. An infra-red (IR) camera was used to assess temperature during cure. DC was assessed spatially (500 μm increments) after curing and in real-time (5.6 Hz) using FTIR-ATR microscopy and spectroscopy, respectively. Multifactorial ANOVA followed by one-way ANOVAs and post hoc Tukey comparisons identified significant differences between test groups (p < 0.05). RESULTS: LCU configuration, PI system and exposure time significantly affected beam transmission, temperature and DC (p < 0.05). The most pronounced effects were seen for the non-homogenous Style/CQ-only combination which exhibited heterogenous spectral irradiance, local temperature changes and cure at 3 s (16 ± 2% DC in zones directly adjacent to 456 nm diodes (DC456 nm) and 0% DC in zones directly adjacent to 408 nm diode (DC408 nm), which was not resolved by 10 s (DC456 nm ≤59 ± 7% and DC408 nm ≤32 ± 15%). Similar effects were seen in materials containing TPO, except DC408 nm > DC456 nm (p < 0.05). Peripheral DC was less than the centre DC in almost all material and light combinations (p < 0.05). Differential cure was only minimised in materials containing combined PIs cured with homogenous beam profiles. Spatial differences in DC were attributed to local spectral properties, heating effects and PI interactions. The early thermal response (<1 s) was due to contribution from the higher optical power at 456 nm diodes, which was faster and greater than the thermal response adjacent to 408 nm diodes irrespective of more efficient TPO activation in this region. SIGNIFICANCE: This study highlights centrally measured transmission, temperature and DC do not reflect local effects, and the importance of spectral and spatial beam irradiance uniformity for curing resin-based materials, as well as appropriately matching LCU output with PIs. An ideal approach to curing large restorations require homogenous beam profiles (power, wavelength and temperature) with appropriate irradiance and exposure times in combination with highly efficient PI systems, appropriate concentrations and broad absorption ranges.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers