Clinical biomechanics (Bristol, Avon)

Ultrasound vibro-elastography for quantitative assessment of ocular tissue biomechanics in patients with idiopathic intracranial hypertension: A pilot study.

Ngoc Thang Bui, Arash Kazemi, Arthur J Sit, Nicholas B Larson, John J Chen, Xiaoming Zhang

Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States of America. · Department of Ophthalmology, Mayo Clinic, Rochester, MN 55905, United States of America.

Key points

From the paper's conclusion
  • These preliminary findings suggest that ultrasound vibro-elastography merits further validation as a noninvasive tool for the assessment of idiopathic intracranial hypertension; the small sample and exploratory design preclude conclusions about clinical application.

Abstract

BACKGROUND: This exploratory pilot study assessed whether ultrasound vibro-elastography can quantify differences in ocular tissue wave speed - a surrogate biomechanical parameter related to tissue stiffness - in patients with idiopathic intracranial hypertension. METHODS: Fourteen patients with idiopathic intracranial hypertension and 21 age-comparable healthy control subjects were studied. The wave speed of the optic nerve head, optic nerve, and posterior sclera was measured noninvasively at 100-200 Hz. Linear mixed-effects models and participant-level analyses accounted for the correlation between fellow eyes; effect sizes with 95% confidence intervals and false-discovery-rate-adjusted P-values are reported. FINDINGS: Wave speed at all three regions was significantly higher in the 14 patients (28 eyes) than in the 21 controls (42 eyes) (optic nerve head at 100 Hz: mean difference 1.57 m/s, 95% CI 1.16-1.97; all adjusted P < 0.003 at the participant level; Cohen's d = 1.3-6.5). In exploratory analyses, eyes with severe papilledema (10 eyes) had higher wave speed at the optic nerve head and optic nerve than eyes with mild papilledema (18 eyes), wave speed correlated with the grade of papilledema (optic nerve head at 100 Hz, participant level: r = 0.66, P = 0.0096), and optic nerve wave speed decreased between baseline and post-intervention in nine treated patients, although the latter did not retain significance after adjustment for multiple comparisons. INTERPRETATION: These preliminary findings suggest that ultrasound vibro-elastography merits further validation as a noninvasive tool for the assessment of idiopathic intracranial hypertension; the small sample and exploratory design preclude conclusions about clinical application.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers