Inter-eye comparison of corneal stiffness parameters in primary open-angle glaucoma patients with unilateral damage.
Yunxiao Sun, Ruiqi Pang, Kai Cao, Ningli Wang, Jing Li
Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China. · Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Key points
From the paper's conclusion- Increased baseline bIOP was correlated with unilateral glaucomatous damage in patients with POAG and HTG. However, a lower corneal stiffness parameter was associated with glaucomatous eyes in NTG. This finding suggests that eyes with a more deformable cornea are vulnerable to glaucomatous damage, even when the IOP is within the normal range.
Abstract
PURPOSE: To investigate inter-eye differences in corneal biomechanical properties as assessed by Corvis ST among primary open-angle glaucoma (POAG) patients with unilateral damage. DESIGN: prospective cross-sectional study. METHODS: This study included 240 eyes from 120 treatment-naïve patients with POAG, of which 60 were classified as normal-tension glaucoma (NTG) and 60 as high-tension glaucoma (HTG). Paired eyes were categorized into glaucomatous eyes and clinically unaffected fellow eyes according to ophthalmic examination. Ocular parameters, including corneal biomechanical properties, were compared between paired eyes within each group (POAG group, NTG and HTG subgroup). The generalized estimation equation (GEE) models with a binary logistic link were employed to examine the association between ocular parameters and the presence of glaucoma. RESULTS: Eyes with POAG had significantly higher biomechanically corrected intraocular pressure (bIOP; p = 0.007), more negative spherical equivalent (SE; p = 0.018), longer axial length (AL; p = 0.006), and thinner central corneal thickness (CCT; p = 0.007) than unaffected fellow eyes. Binocular comparison results differed across subgroups. NTG eyes had significantly thinner CCT (p = 0.015) and lower stiffness parameter at first applanation (SP-A1; p = 0.013) than unaffected fellow eyes. In contrast, HTG eyes showed significantly higher bIOP (p = 0.002), more negative SE (p = 0.047), and longer AL (p = 0.009) compared to controls. Multivariable GEE analysis demonstrated that higher baseline bIOP was significantly associated with the presence of both POAG (odds ratio, 1.111; p = 0.009) and HTG (odds ratio, 1.225; p = 0.002). In the NTG subgroup, lower SP-A1 was the only factor significantly correlated with the presence of glaucoma (odds ratio, 0.985; p = 0.035). CONCLUSIONS: Increased baseline bIOP was correlated with unilateral glaucomatous damage in patients with POAG and HTG. However, a lower corneal stiffness parameter was associated with glaucomatous eyes in NTG. This finding suggests that eyes with a more deformable cornea are vulnerable to glaucomatous damage, even when the IOP is within the normal range.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Corneal Biomechanics in Glaucoma: Current Evidence for Diagnosis, Risk Stratification, and Prognosis.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Role of Corneal Biomechanics in the Pathogenesis, Diagnosis, and Management of Glaucoma.Journal of ophthalmology · 2026
- Evaluation of in vivo subject-specific mechanical behavior of lamina cribrosa in subjects with and without glaucoma.Computer methods in biomechanics and biomedical engineering · 2026
- Corneal Biomechanical Metrics by Corvis ST in a Mexican Population: Normative Data and Population-Specific Implications for Intraocular Pressure Assessment.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Precision and reliability in tonometry: Comparison of Corvis ST and iCare in glaucoma patients on the Ecuadorian coast.Journal francais d'ophtalmologie · 2026
- Intraocular Pressure-Induced Strain in the Posterior Pole of Glaucomatous Eyes: Finite Element Analysis Using Eye-Specific Geometry.Journal of clinical medicine · 2026