Integration of liquid chromatography-tandem mass spectrometry into total laboratory automation: technical challenges and clinical advantages.
Carlos José Sánchez Ovejero, Sergio Luis Lima, Irene Chaves Coira, Alfonso Rey Catena
Department of Clinical Biochemistry, Hospital General Universitario de Guadalajara, Guadalajara, Spain. Electronic address: carlosovej@hotmail.com. · Department of Clinical Laboratory, Complejo Hospitalario Universitario de Canarias, Tenerife, Spain.
Key points
From the paper's conclusion- The clinical laboratory is undergoing a paradigm shift toward the integration of liquid chromatography-tandem mass spectrometry(MS) into Total Laboratory Automation workflows.
Abstract
The clinical laboratory is undergoing a paradigm shift toward the integration of liquid chromatography-tandem mass spectrometry(MS) into Total Laboratory Automation workflows. While historically relegated to specialized satellite units due to manual pre-analytical requirements, recent technological advancements have enabled the development of fully automated, 'sample-to-result' MS modules. This review provides an authoritative analysis of the technical integration of systems such as the Roche cobas® i 601 and Shimadzu CLAM-2040 in core laboratories. We examine the role of intelligent middleware and artificial intelligence-assisted algorithms in ensuring standardized data validation and quality control tracking and real-time operational monitoring. Furthermore, we evaluate the clinical impact of this integration on diagnostic accuracy for low-concentration analytes in endocrinology and therapeutic drug monitoring. By transitioning from batch-based processing to continuous automated streams, MS establishes itself as a robust, high-throughput tool for routine clinical diagnostics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of six serum analyte workflows using routine liquid chromatography-tandem mass spectrometry methods at multiple laboratories with the Cobas i 601 analyzer, an automated mass spectrometry systemClinical Chemistry and Laboratory Medicine (CCLM) · 2026
- Applications of mass spectrometry in the routine diagnostic medical laboratory – a status report 2025Journal of Chromatography B · 2026
- Automation in value-based laboratory medicine: driving precision, capacity, and better outcomesClinical Chemistry and Laboratory Medicine (CCLM) · 2026
- MRM Processor: An Integrated Workflow for Automated MRM Data Processing via Relative Retention Time Correction.Analytical chemistry · 2026
- Analytical strategies for complex injectables: the expanding role of LC-MS technologies.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- B-398 Efficiency and scalability unlocked: multi-channel liquid chromatography integrated with a high-resolution accurate mass time-of-flight mass spec as a new platform for LDTsClinical Chemistry · 2026