Journal of chromatography. A

Hydrophobic natural deep eutectic solvent-based single-drop microextraction for the determination of polycyclic aromatic hydrocarbons in water by gas chromatography-mass spectrometry.

T A Chervonnaya, I U Ukleina, A A Makhmutova, A V Fedotova, A V Peshikova

North-Caucasus Federal University, Stavropol, Stavropol Krai, Russia. Electronic address: cheta97@yandex.ru. · North-Caucasus Federal University, Stavropol, Stavropol Krai, Russia.

Key points

From the paper's conclusion
  • A hydrophobic natural deep eutectic solvent (NADES) composed of menthol and camphor (1:1 molar ratio) was evaluated for the single-drop microextraction (SDME) of sixteen priority polycyclic aromatic hydrocarbons (PAHs) from aqueous samples prior to gas chromatography-mass spectrometry (GC-MS).

Abstract

A hydrophobic natural deep eutectic solvent (NADES) composed of menthol and camphor (1:1 molar ratio) was evaluated for the single-drop microextraction (SDME) of sixteen priority polycyclic aromatic hydrocarbons (PAHs) from aqueous samples prior to gas chromatography-mass spectrometry (GC-MS). Two modes were investigated: direct immersion (DI-SDME) and headspace (HS-SDME). The volatility of both NADES components allows direct injection of the extract into the GC-MS system without back-extraction or solvent evaporation, as menthol and camphor are excluded via a solvent delay. Under optimized conditions, DI-SDME at 40 °C provided recoveries of 74-97% for all sixteen PAHs in real water matrices spiked at LOQ, 50, and 150 ng L⁻¹, with relative standard deviations (RSDs) below 7.8%. The method exhibited high sensitivity, with limits of detection (LODs) of 0.05-1.1 ng L⁻¹ and limits of quantification (LOQs) of 0.17-3.7 ng L⁻¹, fully complying with the EU parametric values for drinking water (Directive 2020/2184) and the environmental quality standard (EQS) for surface waters (Directive 2013/39/EU). The enrichment factors reached 46,000. HS-SDME at 70 °C enabled the selective extraction of low- and medium-volatility 2- to 4-ring PAHs in real samples (recoveries 59-80% at LOQ, 250, and 850 ng L⁻¹), while heavier congeners remained in the aqueous phase. The method was validated using matrix-matched calibration for complex matrices, and AGREE scores of 0.78 (DI-SDME) and 0.74 (HS-SDME) confirmed its environmental sustainability.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers