Analytical methods : advancing methods and applications

Natural deep eutectic solvent-based extraction and on-site smartphone digital image detection of 2-nitrophenol in environmental water samples collected using an unmanned aerial vehicle-based sampling platform.

Gabriel Bercley de Lima Vitorino, Jackson Rodrigo Dos Santos Silva, Severino Marcelino Dos Santos Neto, Marcos Vinícius Foguel, Willian Toito Suarez, Severino Carlos Bezerra de Oliveira, Vagner Bezerra Dos Santos

LIA3 - Laboratory of Instrumentation and Applied Analytical Automation, Department of Fundamental Chemistry, Federal University of Pernambuco, Av. Jornalista Anibal Fernandes, S/N, Cidade Universitária, Recife, PE, 50740-560, Brazil. vagner.bsantos@ufpe.br. · MIPSense Laboratory, Department of Fundamental Chemistry, Federal University of Pernambuco, Recife, PE, Brazil.

Key points

From the paper's conclusion
  • Overall, the workflow provides a practical, portable, reliable, greener, and field-compatible strategy for 2-NP determination in environmental waters.

Abstract

Natural deep eutectic solvents (NADES) have emerged as environmentally-friendly alternatives for sample preparation because of their tunable physicochemical properties, low toxicity, and reduced environmental impact. In this study, a hydrophobic NADES-based analytical workflow integrating liquid-liquid extraction, digital image-based detection (DIB), and unmanned aerial vehicle (UAV)-assisted sampling was developed for the determination of 2-nitrophenol (2-NP) in environmental waters. To the best of our knowledge, no previous study has reported the integration of UAV-based water sampling, NADES extraction with smartphone-based DIB detection of pesticides performed directly in the field. For this, a menthol-decanoic acid NADES (1 : 1 molar ratio) was used as a selective extraction phase for neutral 2-NP, followed by alkaline release into a phosphate solution at pH 12.00, where the yellow 2-nitrophenolate species was generated and quantified using a smartphone. Under optimized conditions of 30.00 mL sample volume and 15.00 min extraction time, the LLE-NADES/DIB method showed a linear response from 0.50 to 7.00 mg L-1 (R2 = 0.9980), with detection and quantification limits of 0.15 and 0.50 mg L-1, respectively. UAV-assisted sampling enabled water collection from four sites without direct operator contact with the sampling environment. Recoveries ranged from 94.6% to 107%, with relative standard deviations below 5.00%. The method also showed high selectivity, with relative errors below 7.00% in the presence of organic and inorganic compounds, while intrinsic matrix coloration did not compromise analyte discrimination. Results were statistically comparable to those obtained by UV-vis spectrophotometry. AGREE and RAPI scores of 0.81 and 90.5, respectively, indicated favorable environmental performance and analytical reliability. Overall, the workflow provides a practical, portable, reliable, greener, and field-compatible strategy for 2-NP determination in environmental waters.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers