Journal of chromatography. A

Development of switchable solvent liquid phase microextraction method for the sensitive detection of pesticide contamination in antarctica lake water.

Süleyman Bodur, Bedrihan Kartoğlu, Sezin Erarpat Bodur, Merve Fırat Ayyıldız, Sezgin Bakırdere

Yıldız Technical University, Faculty of Art and Science, Department of Chemistry, 34220, İstanbul, Türkiye; İstinye University, Faculty of Pharmacy, Department of Analytical Chemistry, 34408, İstanbul, Türkiye. · Yıldız Technical University, Faculty of Art and Science, Department of Chemistry, 34220, İstanbul, Türkiye; İstanbul Nişantaşı University, Department of Basic Sciences, 34398, İstanbul, Türkiye.

Key points

From the paper's conclusion
  • Therefore, monitoring pesticide residues in environmental water samples is very crucial for assessing their environmental and ecological impacts.

Abstract

Pesticides are known to be ubiquitous environmental contaminants that can be transported over long distances and accumulate in remote aquatic ecosystems, including lake waters in the Antarctic region. Therefore, monitoring pesticide residues in environmental water samples is very crucial for assessing their environmental and ecological impacts. This study proposes a switchable solvent liquid-phase microextraction (SS-LPME) method for the preconcentration of selected pesticides prior to their quantification at trace levels by gas chromatography-mass spectrometry (GC-MS). Prior to determining the analytical figures of merit and conducting recovery experiments, all influential parameters, including switchable solvent volume, sodium hydroxide concentration and volume, and sample volume, were optimized using a Box-Behnken experimental design. Under the optimum conditions determined, the limit of quantification (LOQ) values for the analytes ranged from 0.42 to 13.63 µg/kg, while the enhancement in detection power (EDP) varied from 70-fold to 476-fold, depending on the analyte. Furthermore, acceptable recovery results, ranging from 77.9% to 113.4%, were obtained using matrix-matching calibration strategy, with reasonable standard deviation values. Based on these results, the developed analytical method can be safely used to monitor residues of the selected pesticides in environmental lake water samples using either matrix-matching or standard addition calibration methods.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers