A combined QuEChERS extraction/preconcentration methodology for the precise determination of pesticides in wastewater and sludge matrices.
S Ntagkali, K Simeonidis, A Zouboulis, P Samaras
Thessaloniki Regional Center for Plant Protection, Quality and Phytosanitary Control, Thermi, 57001, Greece. · Analytical Chemistry Laboratory, Department of Chemical Engineering, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece. Electronic address: ksime@physics.auth.gr.
Key points
From the paper's conclusion- The effect of matrix was found to be different for the wastewater and sludge with a higher ion suppression response identified for the sludge samples.
Abstract
In this study, an analytical methodology for the determination of pesticides commonly found in sludge and wastewater was developed and validated based on the citrate-buffered QuEChERS (Quick, Easy, Cheap, Effective, Rugged, Safe) extraction procedure. More specifically, to achieve a limit of quantification of 0.001 mg/L in a matrix of synthetic wastewater or sludge, a 1:8 preconcentration was used with the utilization of a rotary evaporator. The method was tested for twelve pesticides identified and quantified via liquid chromatography tandem mass spectrometry (LC/MS-MS) and validated according to the quality control guidelines of the EU SANTE 11312/2021. Obtained measurements provided acceptable linearity, selectivity, sensitivity, precision and accuracy at very low concentrations, indicating the potential of the method to study the fate of pesticides in wastewater and sludge samples, especially those related with fruit processing industry wastes. Recoveries at two fortification levels (0.001 and 0.125 mg/L) ranged 72-107% for the vast majority of the target analytes, with relative standard deviations of less than 20% for all analytes except one. The effect of matrix was found to be different for the wastewater and sludge with a higher ion suppression response identified for the sludge samples.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A versatile modified QuEChERS-LC-MS/MS method for determination of 102 pesticide residues in diverse dried aquatic product matrices and dietary risk assessment.Journal of chromatography. A · 2026
- QuEChERS-Based Multiresidue Pesticide Analysis in Minor Livestock Products and Other Animal-Derived Foods: Performance Evaluation in Selected Matrices and a Market Survey in Korea.Molecules (Basel, Switzerland) · 2026
- Single laboratory validation of multi-residue extraction and cleanup method for analysis of 50 pesticides, 14 veterinary drugs, and 7 Polychlorinated biphenyls in bovine milk by tandem mass spectrometry.Journal of chromatography. A · 2026
- A DoE-optimized QuEChERS-HRMS method for the simultaneous determination of pesticides and pharmaceuticals in dairy products.Analytical methods : advancing methods and applications · 2026
- Assessment of pesticide residues in rice-wheat based conservation agriculture fields using validated LC-MS/MS methodology.Environmental monitoring and assessment · 2026
- Development and validation of a multi-class solid-phase extraction and liquid chromatography tandem mass spectrometry method for emerging contaminants in waterJournal of Chromatography A · 2025