Journal of chromatography. A

Design and fabrication of a molecularly imprinted polymer-modified microfluidic chip for selective extraction and determination of bortezomib.

Reza Mahmoudzadeh Laki, Eslam Pourbasheer, Habibollah Eskandari, Abolghasem Beheshti

Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran; Department of Chemistry, Faculty of Science, University of Mohaghegh Ardabili, P.O. Box 179, Ardabil, Iran. · Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran; Department of Chemistry, Faculty of Science, University of Mohaghegh Ardabili, P.O. Box 179, Ardabil, Iran. Electronic address: e.pourbasheer@uma.ac.ir.

Key points

From the paper's conclusion
  • These results demonstrate that the proposed MIP-modified microfluidic chip is a simple, selective, and efficient platform for bortezomib sample preparation prior to HPLC determination.

Abstract

Development of novel and cost-effective techniques for the selective separation and measurement of target analytes in complex matrices appears to be an urgent need. In this study, a molecularly imprinted polymer-modified microfluidic chip was designed and fabricated for the selective extraction and determination of bortezomib based on HPLC. The chip was fabricated as a glass/polymethyl methacrylate/glass sandwich device in which the polymethyl methacrylate layer defined the microchannel geometry and the glass inner surfaces were modified with a bortezomib-imprinted polymer layer. Surface characterization by SEM confirmed the stepwise surface modification and the formation of a rough and porous MIP layer suitable for selective retention of the analyte. The extraction conditions were optimized using a one-at-a-time approach. Under optimized conditions, the method showed good linearity in the concentration range of 0.01-100 mg L-1 with a correlation coefficient of 0.9997. The limits of detection and quantification were 2.5 and 8.3 µg L-1, respectively, and the repeatability and reproducibility values ​​of the method were 6.7 and 15.5, respectively (n = 3). The method was successfully applied to spiked urine samples and commercial bortezomib injection samples, yielding recoveries of 96.51-100.14% and 102.74-104.57%, respectively, with RSD values ​​of <2.40%. These results demonstrate that the proposed MIP-modified microfluidic chip is a simple, selective, and efficient platform for bortezomib sample preparation prior to HPLC determination.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers