Molecularly imprinted polymer thin-film solid-phase microextraction for biomarkers of anaerobic metabolism of BTEX by microorganisms involved in bioremediation and in microbially influenced corrosion.
Temitope O Nwachukwu, Reza Akhoondi, Christina S Bottaro
Department of Chemistry, Memorial University of Newfoundland, St John's, NL A1B3X7, Canada. cbottaro@mun.ca. · Solid State Pharma, 1489 Hollis Street, Suite 300, Halifax, NS, Canada.
Key points
From the paper's conclusion- The analytical method features multiplexed sample processing, which yields high-throughput extraction and desorption (≥45 samples in 2.7 h or <4 min per sample), combined with a fast (8 min) UHPLC-MS/MS method for the analysis of metabolites associated with microbially influenced corrosion (MIC) and bioremediation.
Abstract
A molecularly imprinted polymer (MIP) composed of 2-vinylpyridine and 1-vinyl-3-ethylimidazolium acetate (FMs) imprinted with homophthalic acid (a pseudo-template (T)) was fabricated directly on a stainless-steel substrate for the selective adsorption of mono- and dicarboxylic acid metabolites of light aromatic components of petrogenic oil from complex aqueous samples. The analytical method features multiplexed sample processing, which yields high-throughput extraction and desorption (≥45 samples in 2.7 h or <4 min per sample), combined with a fast (8 min) UHPLC-MS/MS method for the analysis of metabolites associated with microbially influenced corrosion (MIC) and bioremediation. Notable parameters that influence extraction efficiency, such as ratios of polymer components, extraction time, desorption time, desorption volume, and desorption solvent, were optimized. Polymer morphology, porosity and surface area were determined using scanning electron microscopy (SEM) and nitrogen adsorption porosimetry (Brunauer-Emmett-Teller, BET), respectively. The method achieved limits of detection (LODs) of 0.05-0.2 ng mL-1 and limits of quantitation (LOQs) of 0.1-0.5 ng mL-1 with excellent linearity (R2 > 0.998) over 2-3 orders of magnitude for monocarboxylic acids (e.g., 0.1-500 ng mL-1 for salicylic acid and 0.5-1000 ng mL-1 for o-, p-, and m-toluic acid) and for dicarboxylic metabolites (e.g., 0.5-500 ng mL-1 for phenylsuccinic acid and 0.1-500 ng mL-1 for benzylsuccinic acid). The accuracies from spiked samples ranged from 84.4 to 108% with a %RSD of 1.6-13% for seawater and from 83.6 to 114% with a %RSD of 1.3-10.5% for produced water.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Superior Solid‐Phase Extraction of Methylene Blue Using Engineered Acrylic–Based Molecular Imprinted PolymersJournal of Chemistry · 2026
- Monitoring oil spill contamination in seawater using molecularly imprinted polymer thin-films and direct solid-state fluorometric detection.Environmental monitoring and assessment · 2026
- Molecularly Imprinted Polymer-Based Biosensors for Disease Biomarker Detection and Environmental Monitoring from Fundamental Principles to Emerging Applications.Critical reviews in analytical chemistry · 2026
- Chitosan-Based Molecularly Imprinted Polymers as Functional Adsorbents: Selective m-Cresol Removal from Red WineColloids and Interfaces · 2026
- SiO2-Crosslinked Molecularly Imprinted Hybrid Nanostructures for Solid-Phase Extraction of Bisphenol AACS Applied Nano Materials · 2026