Doping Control Center, Korea Institute of Science and Technology, Hwarang-ro 14-gil 5, Seongbuk-gu, Seoul, 02792, Republic of Korea; Department of Chemistry, Sogang University, Seoul, 04107, Republic of Korea. · Doping Control Center, Korea Institute of Science and Technology, Hwarang-ro 14-gil 5, Seongbuk-gu, Seoul, 02792, Republic of Korea; Department of Chemistry, Dongguk University, Seoul, 04620, Republic of Korea.

Key points

From the paper's conclusion
  • In the present study, background contamination of 39 environmental phenols originating from the HPLC system and sample-preparation materials and reagents was systematically evaluated, along with its impact on quantitative accuracy in human urine.

Abstract

Environmental phenols are ubiquitous environmental contaminants that frequently contaminate analytical systems and sample-preparation materials, thereby compromising quantitative accuracy. In the present study, background contamination of 39 environmental phenols originating from the HPLC system and sample-preparation materials and reagents was systematically evaluated, along with its impact on quantitative accuracy in human urine. Among the 39 environmental phenols investigated, bisphenol A, 4-nitrophenol (PNP), benzophenone-3 (BP-3), bisphenol AF (BPAF), and nonylphenol (NP) originated from the mobile phase and HPLC system. Contaminants originating from sample-preparation materials and reagents included PNP, BP-3, BPAF, methyl paraben, propyl paraben, 4-tert-octylphenol, and NP. Notably, the enzyme (β-glucuronidase/arylsulfatase from Helix pomatia) commonly used for urinary hydrolysis was associated with increased background responses for several analytes. Analysis of NIST SRMs 3672 and 3673 urine samples revealed that the influence of background contamination on quantitative accuracy depended on the specific analyte and its concentration. Furthermore, the correction strategies employed, namely blank subtraction and delay column, did not consistently perform across different analytes and concentrations. Consequently, neither strategy can be assumed to ensure optimal accuracy under all conditions. These findings underscore the need for a systematic assessment of background contamination and empirical validation of correction strategies to ensure the reliable quantification of environmental phenols in human urine, particularly when their concentrations are similar to background contamination levels.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Environmental phenol contaminants originating from the HPLC system and sample-preparation materials, and influence on the quantitative accuracy of phenols in human urine — Science Skim