Extending slalom chromatography from biological DNA to synthetic and modified natural polymers: A case and proof-of-concept study.

Fabrice Gritti, Alexandria Kyranos

Waters Corporation, Core Research/Fundamental, Milford, MA, 01757, USA. Electronic address: Fabrice_Gritti@waters.com. · Waters Corporation, Core Research/Fundamental, Milford, MA, 01757, USA.

Key points

From the paper's conclusion
  • These findings demonstrate that SC columns can be used to fraction any large polymers (>1 MDa) other than dsDNAs with persistence lengths exceeding 100 Å.

Abstract

Slalom chromatography (SC) is a separation technique recently reintroduced to the field of liquid chromatography in 2023. It is so far exclusively dedicated to the characterization of large DNA biopolymers exceeding 1 MDa in molecular mass and is particularly well suited for determining DNA fragment lengths and for separating extensible from compact DNA structures, such as linear versus plasmid DNA. We investigate both the fundamental and practical possibility of analyzing synthetic or chemically modified natural polymers by the same SC separation technique. This approach relies on the core fundamental of SC, that is, the coil-to-stretch transition of any polymer chain under shear flow. From a fundamental perspective, a condition is set on two critical properties of the polymer chain: its contour length and persistence length. The theory is verified by considering the chemically modified natural polymer, hydroxyethyl cellulose (HEC), with a high average molecular weight (> 1 MDa) of unknown distribution and in dilute concentration regime (< 0.01% wt/wt). This experimental validation involves the SC column (GT×ResolveTM 250 Å Slalom Column, MaxPeakTM Premier 2.5μm, 4.6 × 300 mm), distilled water as the mobile phase, along with differential refractive index (dRI) and multiple angle light scattering (MALS) detection to extract gyration radius and molar mass as a function of time. The flow rate was progressively increased from 0.05 mL/min (negligible shear, hydrodynamic chromatography (HDC) retention regime) to 1 mL/min (high shear, SC retention regime). MALS analysis showed that both the gyration radius and the molar mass of the retained HEC fractions increase with retention time, fully consistent with a coil-to-stretch transition of the linear HEC polymer chains induced at high speeds. These findings demonstrate that SC columns can be used to fraction any large polymers (>1 MDa) other than dsDNAs with persistence lengths exceeding 100 Å. SC is expected to be especially useful when in combination with orthogonal analytical techniques such as size-exclusion chromatography (SEC), field-flow fractionation (FFF), or analytical ultracentrifugation (AUC).

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers