From the paper's conclusion- Here, the suitability of polyester capillary-channeled polymer (C-CP) fiber columns operated in hydrophobic interaction chromatographic mode is demonstrated for the routine analysis of extracellular vesicles, using retention time, peak area, and column backpressure as performance metrics.
Abstract
An exponential growth in the interest in extracellular vesicles (EVs) has been observed in recent years, as evidenced by the increasing number of research publications and the growing number of potential EV-based therapeutics in the development pipeline. A current bottleneck in the field, however, remains the need for efficient and reproducible methods for the routine and scalable isolation of EVs. Here, the suitability of polyester capillary-channeled polymer (C-CP) fiber columns operated in hydrophobic interaction chromatographic mode is demonstrated for the routine analysis of extracellular vesicles, using retention time, peak area, and column backpressure as performance metrics. Run-to-run repeatability (single column) and consistency in the fiber column assembly process (column-to-column reproducibility) were demonstrated on 10 analytical columns from 5 assembly batches. Both repeatability and reproducibility showed high consistency, with low relative standard deviations for retention time (<0.6% RSD) and peak area (<4% RSD). Pressure measurements showed greater variability with <7% RSD for run-to-run repeatability and <17% RSD for column-to-column reproducibility. The chromatographic profiles were highly reproducible across all five batches. A previously prepared column (six months old) showed very similar performance to newly made columns, confirming column stability during storage. Method robustness was confirmed over five days on two columns, with inter-day variability of 0.3% RSD for retention time and 1.2% RSD for peak area. A four-minute, "fast" method was developed for scouting analysis conditions and for in-process monitoring of EV levels during cell culture. Finally, the optimal injection volume of the clarified culture medium is established when targeting separation efficiency for subpopulation analysis (4 µL) and optimum injection volume (12 µL) for isolation of bulk EV populations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of throughput and yield characteristics of extracellular vesicles on analytical-scale capillary-channeled polymer fiber columns.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- Monitoring HEK293 cell extracellular vesicle (EV) production via a polyester capillary-channeled polymer (C-CP) fiber column with HIC modalityJournal of Chromatography B · 2026
- A Rapid, High-Resolution Chromatographic Method for Isolating Subpopulations of HEK293-derived Extracellular VesiclesNanotheranostics · 2026
- Tunable purification of plasma extracellular vesicles by multimodal exclusion chromatography for bioanalysis.Talanta · 2026
- Assessment of Protein Removal Efficiency During Isolation of Extracellular Vesicles From Human Plasma Samples Using Size-Exclusion Chromatography.Journal of separation science · 2026
- Comparative evaluation of isolation protocols for Aloe vera-derived extracellular vesiclesFrontiers in Pharmacology · 2026