A 1,4-diazabicyclo[2.2.2]octane-based amphiphilic sulfobetaine stationary phase for versatile mixed-mode liquid chromatography.

Yongxing Hu, Leyu Wang, Pengcheng Zhang, Haoyi Wang, Mengmeng Zhang, Lijun He, Wenjie Zhao

College of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, 450001, PR China. · College of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, 450001, PR China. Electronic address: wjiezh@126.com.

Key points

From the paper's conclusion
  • These results support the mixed-mode selectivity, analytical applicability, and operational stability of Sil-C8-DSB under the evaluated conditions.

Abstract

A novel amphiphilic sulfobetaine-type zwitterionic stationary phase, designated as Sil-C8-DSB, was fabricated via a facile thiol-ene click strategy by anchoring sulfobetaine-functionalized 1,4-diazabicyclo[2.2.2]octane ligands onto thiol-functionalized silica through hydrophobic octyl spacers. 1H and 13C NMR spectroscopy supported the proposed structures of the mono-quaternized intermediate and the C8-DSB ligand, while Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and elemental analysis supported the surface functionalization of Sil-C8-DSB. The retention behavior was investigated using polar, ionizable, and non-polar probe compounds. The effects of acetonitrile content, mobile-phase pH, salt concentration, and temperature indicated combined hydrophilic-interaction, ion-exchange, and reversed-phase retention contributions. Sil-C8-DSB resolved a four-component mixture containing neutral, basic, and acidic probes, whereas co-elution occurred on the commercial HILIC-Z and VP-ODS reference columns under the respective tested conditions. Application to a commercial Sprite sample yielded a sodium benzoate content of 140.2 mg L⁻¹, with recoveries of 97.05-99.14%. Same-column intra-day and inter-day retention-time RSDs were 0.21-0.52% and 0.05-0.76%, respectively, while a 30-day storage test showed no progressive loss of column efficiency. Following a 4 h stop-flow treatment in 50 mM aqueous ammonium acetate, retention times and theoretical plate numbers changed by <1%, with baseline separation maintained. These results support the mixed-mode selectivity, analytical applicability, and operational stability of Sil-C8-DSB under the evaluated conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers