Controllable preparation of zwitterionic-functionalized stationary phases by surface-initiated atom transfer radical polymerization for hydrophilic interaction liquid chromatography (HILIC).
Tomoaki Shimpo, Tohru Ikegami
Faculty of Molecular Chemistry and Engineering, Kyoto Institute of Technology, Matsugasaki, Kyoto, Sakyo-ku, 606-8585, Japan; LC Business Unit of Life Science Business Department, Analytical & Measuring Instruments Division, Shimadzu Corporation, 1, Nishinokyo Kuwabara-cho, Kyoto, Nakagyo-ku, 604-8511, Japan. · Faculty of Molecular Chemistry and Engineering, Kyoto Institute of Technology, Matsugasaki, Kyoto, Sakyo-ku, 606-8585, Japan. Electronic address: ikegami@kit.ac.jp.
Key points
From the paper's conclusion- Overall, this study reorganizes the meanings of retention factor and selectivity employed in the HILIC test and provides a framework for interpreting the different physicochemical information represented by the individual HILIC test parameters.
Abstract
Fifteen novel zwitterionic-functionalized columns for HILIC were prepared by surface-initiated atom transfer radical polymerization (SI-ATRP) and three bare silica columns made from different porous silica particles with mesopore sizes of 100, 200, and 300 Å. These columns were comprehensively characterized by the Ikegami test, taking into account the multiple interactions involved in HILIC: partition, adsorption, and electrostatic interactions. The results suggested that the phase ratio (β) and k(uridine), k(U), primarily reflect the overall scale of hydrophilic retention, whereas α(uridine/2'-deoxyuridine, selectivity for OH) and α(uridine/5-methyluridine, selectivity for CH₂) mainly represent hydrophilic recognition. In contrast, selectivity factors related to shape selectivity and ion-exchange interactions were found to be more responsive to the local interfacial environment. Furthermore, although positive approximately linear relationships were observed between β and k(U) within each mesopore-size series, the experimentally observed β-k(U) relationships were not identical among the three mesopore-size series. Overall, this study reorganizes the meanings of retention factor and selectivity employed in the HILIC test and provides a framework for interpreting the different physicochemical information represented by the individual HILIC test parameters.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cross‐Linked Poly(acrylic acid) Stationary Phase via Surface‐Initiated Atom Transfer Radical Polymerization for Hydrophilic Interaction ChromatographySEPARATION SCIENCE PLUS · 2026
- Systematic Evaluation of Partition-Dominated Retention in Hydrophilic Interaction Liquid Chromatography (HILIC) Under Varying Aqueous Components of the Mobile Phase: Revisiting the HILIC Column Test Scheme.Journal of separation science · 2026
- Condition Dependence of Ion-Exchange-Related Retention in Hydrophilic Interaction Liquid Chromatography (HILIC): Revisiting the HILIC Test Scheme.Journal of separation science · 2026
- Analysis of adsorption equilibria and surface energetic properties of stationary phases in selected hydrophilic interaction liquid chromatography systemsAdvances in Science and Technology – Research Journal · 2026
- Impact of sulfonium versus ammonium groups in zwitterions on hydrophilic interaction chromatographic separation performance.Journal of chromatography. A · 2026
- Evaluation of a Hydrophilic Interaction Liquid Chromatography Design Space for Amino Acids.Journal of separation science · 2026