Beyond fixed serum vitamin B12 thresholds: A multivariable risk approach to reflex methylmalonic acid testing (NHANES 2011-2014).
Zhenghan Huang
Department of Clinical Laboratory, The First People's Hospital of Kunming, Kunming, Yunnan, China. Electronic address: 523173800@qq.com.
Key points
From the paper's conclusion- Single B12 thresholds had limited sensitivity and no kidney-stratified threshold system was supported or validated. A multivariable model-using only B12 and eGFR-showed better discrimination and apparent net benefit than fixed cutoffs. Post-hoc grey-zone refits showed gains, but the frozen full-sample model showed poor grey-zone calibration; external validation is required before clinical use.
Abstract
BACKGROUND: Reflex methylmalonic acid (MMA) testing is usually guided by fixed B12 thresholds, which may fail when kidney function is impaired. METHODS: We analysed 10,174 NHANES 2011-2014 adults with complex-survey weighting. Four prespecified B12 cutoffs were compared with multivariable logistic models for elevated MMA (≥271 nmol/L) using decision curve analysis. RESULTS: Weighted prevalence of elevated MMA was 8.9%. The 221 pmol/L cutoff had sensitivity 33.4% (9.4% at eGFR <45). Discrimination rose across a comparator ladder: dichotomised B12 0.623, continuous B12 0.690, B12 + eGFR 0.805, full model 0.819. ΔAUC over B12 alone was 0.128 (JKn 95% CI 0.100-0.157) overall and 0.052 (JKn 95% CI 0.032-0.071) with eGFR ≥60; post hoc temporal validation preserved discrimination (validation AUC 0.817). Grey-zone-refitted models retained discrimination (optimism-corrected AUC 0.71 for B12 + eGFR); frozen full-sample models were modest (AUC 0.651 two-variable, 0.669 full) and require local recalibration. At a 5% risk threshold the full model detected 83.2% of cases versus 33.4% for the cutoff-7.6 additional tests per additional case. Continuous-scale kidney-function interaction was sensitive to the test denominator (p = 0.028-0.096). CONCLUSIONS: Single B12 thresholds had limited sensitivity and no kidney-stratified threshold system was supported or validated. A multivariable model-using only B12 and eGFR-showed better discrimination and apparent net benefit than fixed cutoffs. Post-hoc grey-zone refits showed gains, but the frozen full-sample model showed poor grey-zone calibration; external validation is required before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Vitamin B12 biomarker patterns and kidney function in US adults: National Health and Nutrition Examination Survey 2011-2012.Laboratory medicine · 2026
- B-048 Optimizing vitamin B12 deficiency detection: Evaluation of HoloTC-based reflex strategies to improve diagnostic performance and test utilizationClinical Chemistry · 2026
- Refining MMA Screening in the Dutch Newborn Screening Program: Lessons from Vitamin B12 Deficiency and Genetic Cases.International journal of neonatal screening · 2026
- Hypercobalaminemia in Outpatient Practice.Journal of clinical medicine · 2026
- Simultaneous Quantification of Total Homocysteine and Methylmalonic Acid by LC-MS/MS for Comprehensive Assessment of Vitamin B12 and Folate deficiencies.Biochimie · 2026
- Vitamin B12 and one-carbon biomarker assay interference: a systematic review, with a consensus-derived diagnostic algorithm proposed for Gulf primary careFrontiers in Molecular Biosciences · 2026