Clinica chimica acta; international journal of clinical chemistry

Biological variation estimates of laboratory assays for von Willebrand disease, including von Willebrand factor activity using VWF:GPIbM.

Róisín Spriggs, Lorna Power, Maeve P Crowley, James V Harte

EOLAS Research Group, Cork University Hospital, Wilton, Cork, Ireland; Department of Haematology, Cork University Hospital, Wilton, Cork, Ireland. · Department of Haematology, Cork University Hospital, Wilton, Cork, Ireland.

Key points

From the paper's conclusion
  • However, BV data for haemostasis measurands remain limited, particularly for laboratory assays used in the investigation of investigation and diagnosis of von Willebrand disease (VWD).

Abstract

Estimates of biological variation (BV) provide an important basis for establishing performance specifications. However, BV data for haemostasis measurands remain limited, particularly for laboratory assays used in the investigation of investigation and diagnosis of von Willebrand disease (VWD). As such, we study aimed to estimate the variation associated with VWF and FVIII measurands and to derive BV-based performance specifications. Fourteen healthy adults were sampled weekly for four consecutive weeks. VWF antigen (VWF:Ag), VWF activity (VWF:Ac) - including ristocetin cofactor activity (VWF:RCo) and gain-of-function mutant GPIb activity (VWF:GPIbM) - and FVIII coagulant activity (FVIII:C) were measured on a Sysmex CN3500 analyser (Kobe Japan). Data were analysed using the recently developed BV Calculator to estimate analytical (CVA), within subject (CVI) and between-subject (CVG) variations. Reference change values and analytical performance specifications were also subsequently derived. The estimated CVI and CVG were 5.9% (95% CI, 4.8-7.5%) and 26.8% (19.2-44.7%) for VWF:Ag; 9.5% (7.6-12.4%) and 34.6% (24.5-58.9%) for VWF:RCo; 5.2% (4.3-6.8%) and 33.7% (24.0-56.9%) for VWF:GPIbM; and 9.9% (8.1-12.7%) and 20.5% (14.3-34.2%) for FVIII:C, respectively. CVI estimates were generally lower than corresponding meta-analysis estimates for VWF:Ag and both VWF:Ac assays, whereas the CVI estimate for FVIII:C was broadly comparable. Consequently, the derived specifications were generally more stringent than those based on existing estimates. This study provides additional estimates of BV for laboratory assays used in the investigation of VWD, including VWF:GPIbM - which have not been previously published. Further studies are warranted to assess the generalisability of these estimates.

Read the paper