Interassay and interlaboratory comparison of von Willebrand factor antigen as a diagnostic and prognostic biomarker in advanced chronic liver disease.

Lorenz Balcar, Alberto Zanetto, Jelle Adelmeijer, Benedikt Simbrunner, Elena Matthey, Cristiana Bulato, Maxime Zermatten, Kerstin Zinober,

Division of Gastroenterology and Hepatology, Department of Medicine III, Medical University of Vienna, Vienna, Austria. · Gastroenterology and Multivisceral Transplant Unit, Department of Surgery, Oncology, and Gastroenterology, Padova University Hospital, Padova, Italy.

Key points

From the paper's conclusion
  • Our head-to-head comparison indicates that the widespread introduction of VWF:Ag and VITRO score into clinical practice may rely on existing infrastructure, as commonly used diagnostic assays either yielded consistent, or in case of Siemens, easily convertible results. For ruling-in CSPH in cACLD by VITRO, no conversion is required.

Abstract

BACKGROUND: Von Willebrand factor antigen (VWF:Ag) is an inexpensive assay that is broadly available in diagnostic laboratories. The ratio of von Willebrand factor antigen and platelet count (VITRO) score (VWF:Ag/platelet count ratio) is the most promising blood-based test for clinically significant portal hypertension (CSPH) in compensated advanced chronic liver disease (cACLD). However, most published data are based on the Stago VWF:Ag assay. To allow widespread clinical application, we performed a comparative study with other commonly used assays. METHODS: We included 353 patients with cACLD and decompensated cirrhosis undergoing hepatic venous pressure gradient measurement. Frozen citrated plasma samples were provided to centers with expertise in hemostasis and coagulation tests applying different assays (ie, Stago-Groningen, Werfen/IL-Padova, and Siemens-Lausanne). RESULTS: Mean differences between VWF:Ag and VITRO levels of Stago vs Siemens were 49.6 (95% CI, 43.9-55.3) % vs 0.59 (95% CI, 0.51-0.67) and between those of Stago vs Werfen/IL were 12.1 (95% CI, 5.7-18.5) % vs 0.18 (95% CI, 0.10-0.26). Stago and Werfen/IL (intraclass correlation, 0.911; r, 0.914) as well as Siemens (intraclass correlation, 0.921; r, 0.922) showed near perfect correlation. Systematically lower VWF:Ag values by the Siemens assay are amendable by a newly developed conversion formula for patients with ACLD. Among patients with cACLD and Child-Turcotte-Pugh stage A, VITRO scores yielded consistently high areas under the curve (Stago: 0.865; Werfen/IL: 0.865; Siemens: 0.855). Using the previously established VITRO score cutoff of ≥2.5 to rule in CSPH, the positive predictive value was >90% with all assays. CONCLUSION: Our head-to-head comparison indicates that the widespread introduction of VWF:Ag and VITRO score into clinical practice may rely on existing infrastructure, as commonly used diagnostic assays either yielded consistent, or in case of Siemens, easily convertible results. For ruling-in CSPH in cACLD by VITRO, no conversion is required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers