From promise to practice: Assessing middleware characteristics in autoimmune diagnostics.
Emirena Garrafa, Brunetta Porcelli, Valentina Muraro, Rocco Negri, Barbara Casolari, Maria Infantino, Giampaola Pesce, Nicola Bizzaro
Department of Molecular and Translational Medicine, University of Brescia, Brescia, Italy; Department of Laboratory Diagnostics, ASST Spedali Civili, Brescia, Italy. Electronic address: emirena.garrafa@unibs.it. · Pathology Unit, Siena University Hospital, Siena, Italy.
Key points
From the paper's conclusion- We conducted a nationwide descriptive survey to characterize middleware adoption, reported functionality, and user perceptions in Italian autoimmune diagnostic laboratories affiliated with the Autoimmunology Study Group of the Italian Society of Clinical Pathology and Laboratory Medicine.
Abstract
Middleware systems connect analytical instruments with laboratory information systems and may support workflow control, result review, and data management. We conducted a nationwide descriptive survey to characterize middleware adoption, reported functionality, and user perceptions in Italian autoimmune diagnostic laboratories affiliated with the Autoimmunology Study Group of the Italian Society of Clinical Pathology and Laboratory Medicine. The questionnaire was administered in January 2026. Of 38 invited laboratories, 36 responded and 33 reported using middleware. Thirty laboratories provided complete Yes/No/I-don't-know responses for 24 detailed functionality items. Cross-vendor interoperability was reported in 20 of 29 records (69.0%); six reported no interoperability and three were nonresponses. Reported capabilities varied: worklist generation (70.0%), previous-result display (86.7%), personalized comments (80.0%), remote assistance (83.3%), and online updates (80.0%) were common, whereas warehouse management (3.3%), access to the clinical question (6.7%), delta-check flagging (13.3%), redundant-test cancellation (20.0%), and automated dilution suggestions (20.0%) were less common. Agreement (Likert scores 4-5) with perceived benefits ranged from 54.2% for reduction of reporting errors to 88.5% for improved diagnostic quality. These findings describe respondent-reported capabilities and perceived benefits; they do not demonstrate objective improvements in quality, turnaround time, error rates, or patient outcomes. The results identify potential priorities for interoperability, configurable rules, user training, and future objective evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-138 Implementing Likelihood Ratios in Autoimmune Diagnostics: Early Experiences from Laboratories and CliniciansClinical Chemistry · 2026
- Automation and artificial intelligence in the clinical microbiology laboratory.Frontiers in cellular and infection microbiology · 2026
- B-241 AUTOMATING REPORTS TO MONITOR LABORATORY STABILITY AND DEFECTSClinical Chemistry · 2026
- B-037 Technical Operations Center 4.0: Pioneering End-to-End Laboratory Automation in Brazil to Increase Capacity, Operational Efficiency, and SustainabilityClinical Chemistry · 2026
- From spreadsheets and scripts to controlled software lifecycles: recommendations for laboratory-developed software under ISO 15189 and IVDR.Clinical chemistry and laboratory medicine · 2026
- Integration of liquid chromatography-tandem mass spectrometry into total laboratory automation: technical challenges and clinical advantages.Clinical biochemistry · 2026