Robotic-assisted versus manual percutaneous coronary intervention after contemporary randomized evidence: An updated systematic review and meta-analysis of patient-level procedural and radiation outcomes.
Kumail Razvi, Maroun Ibrahim, Umer Irshad, Ramza Ishac, Zunaira Shah, Ahmad Al Taweel, Bahaeddine Shabaneh, Molham Aldeiri
University of Houston, HCA Clear Lake, Webster, TX, USA. · University of Houston, HCA Clear Lake, Webster, TX, USA. Electronic address: marounibrahim29@gmail.com.
Key points
From the paper's conclusion- R-PCI has not shown consistent patient procedural or radiation benefit. Operator protection is supported descriptively but was not pooled; contrast reduction appeared only in sensitivity analysis. Future trials should assess patient benefit and team-wide occupational exposure.
Abstract
BACKGROUND: Robotic-assisted PCI (R-PCI) reduces measured radiation exposure to the primary operator, but procedural and patient-radiation benefits over manual PCI (M-PCI) remain uncertain. OBJECTIVES: To compare procedural/PCI time, fluoroscopy time, contrast volume, air kerma, and dose-area product between R-PCI and M-PCI after incorporation of randomized evidence. METHODS: Randomized and nonrandomized comparative studies of adults undergoing PCI were included. Random-effects models used restricted maximum likelihood with modified Hartung-Knapp inference. Mean differences (MDs) were calculated as M-PCI minus R-PCI. Risk of bias was assessed using RoB 2 and ROBINS-I; certainty was assessed using GRADE. RESULTS: Twelve studies, including 2 randomized trials, contributed data. No primary pooled outcome differed significantly: procedural/PCI time, MD -3.90 min (95% CI: -16.15 to 8.35); fluoroscopy time, 0.17 min (95% CI: -2.61 to 2.95); contrast volume, 7.79 mL (95% CI: -3.08 to 18.66); air kerma, 232.01 mGy (95% CI: -145.67 to 609.70); and dose-area product, 31.31 dGy·cm2 (95% CI: -49.45 to 112.07). Heterogeneity was substantial (I2 = 72%-93%). A direct-report-only analysis favored R-PCI for contrast volume (MD: 17.76 mL; 95% CI: 4.62-30.90), but other sensitivity analyses did not materially change interpretation. Certainty was very low for all outcomes. CONCLUSIONS: R-PCI has not shown consistent patient procedural or radiation benefit. Operator protection is supported descriptively but was not pooled; contrast reduction appeared only in sensitivity analysis. Future trials should assess patient benefit and team-wide occupational exposure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Procedural and Clinical Outcomes of Second-generation Robotic-assisted versus Manual Percutaneous Coronary Intervention: A 1-year Follow-up Study.Interventional cardiology (London, England) · 2026
- Comparative Outcomes of Robotic-Assisted Versus Manual Percutaneous Coronary Intervention Using a Four-Channel Robotic Platform.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Robot-assisted versus manual percutaneous vascular interventions across vascular territories: a systematic review and meta-analysis.Journal of robotic surgery · 2026
- Robot-assisted versus manual neuroendovascular interventions - updated systematic review and pairwise meta-analysis.AJNR. American journal of neuroradiology · 2026
- Comparison of Robotic and Manual Percutaneous Coronary Intervention in Complex Coronary Artery Disease: A Propensity‐Matched AnalysisJournal of Interventional Cardiology · 2026
- Robotic-Assisted versus Manual Diagnostic Cerebral Angiography: Comparative Outcomes and Learning Curve in a Large Single-Institution Cohort.AJNR. American journal of neuroradiology · 2026