Cardiovascular revascularization medicine : including molecular interventions

Robotic-assisted versus manual percutaneous coronary intervention after contemporary randomized evidence: An updated systematic review and meta-analysis of patient-level procedural and radiation outcomes.

Kumail Razvi, Maroun Ibrahim, Umer Irshad, Ramza Ishac, Zunaira Shah, Ahmad Al Taweel, Bahaeddine Shabaneh, Molham Aldeiri

University of Houston, HCA Clear Lake, Webster, TX, USA. · University of Houston, HCA Clear Lake, Webster, TX, USA. Electronic address: marounibrahim29@gmail.com.

Meta-analysis

Key points

From the paper's conclusion
  • R-PCI has not shown consistent patient procedural or radiation benefit. Operator protection is supported descriptively but was not pooled; contrast reduction appeared only in sensitivity analysis. Future trials should assess patient benefit and team-wide occupational exposure.

Abstract

BACKGROUND: Robotic-assisted PCI (R-PCI) reduces measured radiation exposure to the primary operator, but procedural and patient-radiation benefits over manual PCI (M-PCI) remain uncertain. OBJECTIVES: To compare procedural/PCI time, fluoroscopy time, contrast volume, air kerma, and dose-area product between R-PCI and M-PCI after incorporation of randomized evidence. METHODS: Randomized and nonrandomized comparative studies of adults undergoing PCI were included. Random-effects models used restricted maximum likelihood with modified Hartung-Knapp inference. Mean differences (MDs) were calculated as M-PCI minus R-PCI. Risk of bias was assessed using RoB 2 and ROBINS-I; certainty was assessed using GRADE. RESULTS: Twelve studies, including 2 randomized trials, contributed data. No primary pooled outcome differed significantly: procedural/PCI time, MD -3.90 min (95% CI: -16.15 to 8.35); fluoroscopy time, 0.17 min (95% CI: -2.61 to 2.95); contrast volume, 7.79 mL (95% CI: -3.08 to 18.66); air kerma, 232.01 mGy (95% CI: -145.67 to 609.70); and dose-area product, 31.31 dGy·cm2 (95% CI: -49.45 to 112.07). Heterogeneity was substantial (I2 = 72%-93%). A direct-report-only analysis favored R-PCI for contrast volume (MD: 17.76 mL; 95% CI: 4.62-30.90), but other sensitivity analyses did not materially change interpretation. Certainty was very low for all outcomes. CONCLUSIONS: R-PCI has not shown consistent patient procedural or radiation benefit. Operator protection is supported descriptively but was not pooled; contrast reduction appeared only in sensitivity analysis. Future trials should assess patient benefit and team-wide occupational exposure.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers