Comparative Outcomes of Robotic-Assisted Versus Manual Percutaneous Coronary Intervention Using a Four-Channel Robotic Platform.
Junghoon Lee, Daeung Ohn, Sook Jung Kim, Yeon-Jik Choi, Osung Kwon, Jeong-Eun Yi, Sung-Won Jang, Suk-Min Seo
Department of Internal Medicine, Division of Cardiology, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Key points
From the paper's conclusion- R-PCI with a four-channel platform was feasible and safe, with lower operator radiation, lower workload, and lower per-minute patient exposure, and allowed remote dual-wire side-branch protection.
Abstract
BACKGROUND: Robotic-assisted PCI (R-PCI) reduces operator radiation and physical workload. Existing platforms operate a single guidewire at a time, and comparative data on R-PCI in situations that require a second wire for side-branch protection are lacking. AIMS: We evaluated the feasibility and safety of R-PCI using a four-channel platform, compared with manual PCI (M-PCI), in elective single-vessel PCI. METHODS: In this single-center pilot study, 40 patients were enrolled (M-PCI, n = 30; R-PCI, n = 10). The four-channel architecture enabled remote dual-wire side-branch protection in 3 of the 10 R-PCI cases. Procedure time, operator and patient radiation, contrast volume, NASA Task Load Index (NASA-TLX), and CK-MB and troponin-I at 6 and 12 h were recorded. Pre-specified per-minute rates were calculated. Groups were compared with the Mann-Whitney U test. RESULTS: Technical and clinical success were 100%, with no conversion to manual operation and no device-related adverse events. R-PCI procedures were longer than M-PCI (33.3 ± 11.4 vs. 26.0 ± 15.1 min; p = 0.027). Operator radiation outside the lead apron was 92% lower with R-PCI (p < 0.001). Cumulative patient radiation and contrast did not differ significantly, but per-minute rates were lower for contrast (-43%; p < 0.001), DAP (-35%; p = 0.002), and air kerma (-42%; p < 0.001). Operator workload (NASA-TLX) was 68% lower (p = 0.002). Post-procedural CK-MB was lower at 6 and 12 h (p = 0.049 and 0.044), and troponin-I followed the same direction without reaching significance. CONCLUSIONS: R-PCI with a four-channel platform was feasible and safe, with lower operator radiation, lower workload, and lower per-minute patient exposure, and allowed remote dual-wire side-branch protection. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT06735716 (LNR-AVIARMX2-I02). Registered prior to first patient enrollment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Robotic-assisted versus manual percutaneous coronary intervention after contemporary randomized evidence: An updated systematic review and meta-analysis of patient-level procedural and radiation outcomes.Cardiovascular revascularization medicine : including molecular interventions · 2026
- Procedural and Clinical Outcomes of Second-generation Robotic-assisted versus Manual Percutaneous Coronary Intervention: A 1-year Follow-up Study.Interventional cardiology (London, England) · 2026
- Comparison of Robotic and Manual Percutaneous Coronary Intervention in Complex Coronary Artery Disease: A Propensity‐Matched AnalysisJournal of Interventional Cardiology · 2026
- Evaluating Patients' Profiles and Procedural Outcomes of Robotically Assisted Percutaneous Coronary Interventions: A Single Centre Experience.Journal of clinical medicine · 2026
- Robotic-Assisted versus Manual Diagnostic Cerebral Angiography: Comparative Outcomes and Learning Curve in a Large Single-Institution Cohort.AJNR. American journal of neuroradiology · 2026
- Robot-assisted versus manual percutaneous vascular interventions across vascular territories: a systematic review and meta-analysis.Journal of robotic surgery · 2026