Biotechnology reports (Amsterdam, Netherlands)

Efficient filtration of fibrinogen solution by a virus removal filter.

Tomona Harada, Kumiko Michikawa, Mana Konno, Takeshi Yokoyama, Mikihiro Yunoki, Daisuke Miyamoto

Technology Development Department, R&D and Business Development, Asahi Kasei Life Science Corporation, Miyazaki, Japan. · Research and Development Division, Japan Blood Products Organization, Tokyo, Japan.

Key points

From the paper's conclusion
  • Notably, Planova 20 N filter exhibited robust virus removal performance and the biological activity of fibrinogen including its clotting function was preserved, indicating that protein integrity was maintained throughout the process.

Abstract

Historically, achieving efficient filtration of fibrinogen solutions using virus removal filters has been challenging due to the fibrinogen's tendency to aggregate and its molecular size and structure. In this study, the feasibility of fibrinogen using the filtration the Planova™ 20 N filter and its virus removal efficacy under optimized filtration conditions were investigated. Optimization of arginine (400 mM) and fibrinogen (2 mg/mL) concentration in the solution, along with pre-filtration to remove the aggregates, was essential for achieving efficient filtration. Notably, Planova 20 N filter exhibited robust virus removal performance and the biological activity of fibrinogen including its clotting function was preserved, indicating that protein integrity was maintained throughout the process.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers